5 — SDO: Monitor Profile Objects
parameter
Analog1 Resistor Value
Analog2 Resistor Value
Analog3 Resistor Value
Analog4 Resistor Value
Analog5 Resistor Value
Analog1 Voltage Value
Analog2 Voltage Value
Analog3 Voltage Value
Analog4 Voltage Value
Analog5 Voltage Value
Battery Voltage
Driver1 Current
Driver2 Current
Total Driver Current
PWM1
PWM2
Hour Meter
Switch Input Status
Virtual Digital Input Status
5V Voltage
12V Voltage
Ext Current
Pulse Count
RPM
Position
38
MONITOR PARAMETER PROFILE OBJECTS
The Monitor Parameter Profile Objects are shown in Table 4.
Table 4 Monitor Profile Object Dictionary
sdo location
-
index
sub
index
0x3100
0x00
0x3101
0x00
0x3102
0x00
0x3103
0x00
0x3104
0x00
0x3110
0x00
0x3111
0x00
0x3112
0x00
0x3113
0x00
0x3114
0x00
0x3120
0x00
0x3130
0x00
0x3131
0x00
0x3132
0x00
0x3140
0x00
0x3141
0x00
0x3150
0x00
0x3160
0x00
0x3170
0x00
0x3180
0x00
0x3181
0x00
0x3182
0x00
0x3190
0x00
0x3191
0x00
0x3192
0x00
Curtis 1356/1356P CAN Expansion Module Manual,
range
can value
description
0 – 7500 Ω
Resistive type analog input value.
0 – 7500
Scale returned as 1 ohm per count.
See above.
See above.
See above.
See above.
See above.
See above.
See above.
See above.
0.00 – 15.60 V
Voltage type analog input value.
0 – 1560
Scale returned as 0.01 volt per count.
See above.
See above.
See above.
See above.
See above.
See above.
See above.
See above.
0.0 – 120.0 V
Voltage as read by the 1356 / 1356P.
0 – 1200
0.00 – 3.00 A
Present current sunk by Driver 1.
0 – 300
0.00 – 1.00 A
Present current sunk by Driver 2.
0 – 100
0.00 – 4.00 A
Present current sunk by both drivers.
0 – 400
0.0 – 100.0 %
Present PWM % of Driver 1.
0 – 1000
See above.
Present PWM % of Driver 2.
0 – 65535 h
Present value of the hour meter.
0 – 65535
0 – 0x1FFF
Status of switch inputs (LSB for switch
0 – 0x1FFF
Input 1: 1 = High, 0 = Low.
0 – 0x1F
Status of virtual switch inputs (LSB for
0 – 0x1F
input 1: 1 = High, 0 = Low.
0.0 – 6.3 V
Voltage value of the +5V output.
0 – 63
0.0 – 16.0 V
Voltage value of the +12V output.
0 – 160
0 – 250 mA
Total current on +5V and +12V
0 – 250
outputs.
Current encoder pulse count.
-2
– 2
-1
Negative count indicates the
29
29
-2
– 2
-1
encoder is running in the reverse
29
29
direction of the zero position.
Encoder RPM in revolutions per
0 – 65535 rpm
minute when encoder is configured
0 – 65535
as RPM type.
Calculated position value according
-32.768 – 3 2.767 m
to the pulse per meter when encoder
-32768 – 32767
is configured as Position type.