6.2
Connecting the power supply.
• Remove the front cover.
• Mount cable gland in the front cover.
• Insert power cable through cable gland and front
cover.
• Connect power cable to power board (see fig.
6.1.1 / 6.2.1).
• Mount front cover in desired position (see fig.
6.2.1).
• Install cable gland and mount the cover
6.2.1 Connect power cable to power board
For pipe connection see fig. 6.2.2.
6.2.2 Pipe connection
14
Installation Operation & Maintenance manual ELQ
6.3
Main fuse replacement
table 6.2 Internal main fuse ELQ-actuators
Actuator
ELQ 100/200/300/500/800
6.3.1 Main fuse
Important
After adjustments always mount the cover to
the housing.
Take care that the cover seal is in place to
comply to dust and water tightness according
to IP65, IP67 or NEMA4.
DOC.55.EDN Rev: E
October 2012
Fuse type Dim.
T 10 A
ø 5 x 20 mm