Emerson Fisher Y696VR Series Instruction Manual

Vacuum regulators

Advertisement

Quick Links

Instruction Manual
D102662X012
January 2019
Y696VR Series Vacuum Regulators
WARNING
!
Failure to follow these instructions or
to properly install and maintain this
equipment could result in an explosion,
fire and/or chemical contamination
causing property damage and personal
injury or death.
Fisher™ regulators must be installed,
operated, and maintained in accordance
with federal,state, and local codes,
rules and regulations, and Emerson
Process Management Regulator
Technologies Inc. instructions.
If the regulator vents gas or a leak
develops in the system, service to
the unit may be required. Failure
to correct trouble could result in a
hazardous condition.
Installation, operation, and maintenance
procedures performed by unqualified
personnel may result in improper
adjustment and unsafe operation. Either
condition may result in equipment
damage or personal injury. Use
qualified personnel when installing,
operating, and maintaining the
Y696 Series regulator.
Introduction
Scope of Manual
This manual describes and provides instructions and
parts lists for the Type Y696VR and the Type Y696VRM
vacuum regulators. Instructions and parts lists for
other equipment used with these breakers are found in
separate manuals.
W7431
Figure 1. Type Y696VR Vacuum Regulator
Product Description
The Y696VR Series direct-operated vacuum regulators
are used for precise control of small capacity,
low-pressure service applications where an increase
in vacuum must be limited. They are described
as follows:
Type Y696VR—The Type Y696VR has internal
pressure registration requiring no downstream
control line.
Type Y696VRM—The Type Y696VRM has a control
line connection and an O-ring stem seal blocking the
throat for external pressure registration.
Y696VR Series

Advertisement

Table of Contents
loading

Summary of Contents for Emerson Fisher Y696VR Series

  • Page 1 Fisher™ regulators must be installed, operated, and maintained in accordance with federal,state, and local codes, rules and regulations, and Emerson Process Management Regulator Technologies Inc. instructions. W7431 If the regulator vents gas or a leak develops in the system, service to Figure 1.
  • Page 2: Specifications

    Y696VR Series Specifications Some general ratings and specifications for the Y696VR Series vacuum regulators are given on page 2. Individual regulators from the factory are supplied with the specific data stamped on the nameplate. Body Sizes and End Connection Styles Spring Case Connection See Table 1 3/4 NPT...
  • Page 3: Principle Of Operation

    Y696VR Series Note If this equipment is shipped mounted on another unit, install the unit according to VACUUM BEING CONTROLLED the appropriate instruction manual. 1. Only personnel qualified through training and experience should install, operate, and maintain this equipment. For Y696VR Series equipment that is shipped separately, make sure that there is no damage to or foreign material in it.
  • Page 4 Y696VR Series Table 2. Vacuum Control Pressure Ranges and Spring Part Numbers VACUUM CONTROL CHANGE IN VACUUM CONTROL SPRING SPRING PRESSURE RANGE PRESSURE TO REACH WIDE-OPEN WIRE DIAMETER SPRING COLOR PART NUMBER In. w.c. mbar In. w.c. mbar 1 to 3 2 to 7 1D892527022 Brown...
  • Page 5 Y696VR Series Table 3. Disk Holder Assembly Materials and Part Numbers (key 25) TRIM MATERIAL DISK MATERIAL DISK ASSEMBLY 303 Stainless steel (standard) Nitrile (NBR) 1D6405000D2 316 Stainless steel Perfluoroelastomer (FFKM) Disk: 1D6404X0022, Disk Holder: 1D6403X0032 N10276 Hastelloy Polytetrafluoroethylene (PTFE) 1D6405X0152 ®...
  • Page 6: Parts Ordering

    Y696VR Series Parts List 4. To replace the lever assembly (key 9), remove the machine screws (key 11) and lever pin. Description Part Number 5. To replace the valve stem (key 13) or stem seal Spring O-ring (key 15) remove the valve stem from the 1 to 3 in.
  • Page 7 Y696VR Series A7175 TYPE Y696VR ASSEMBLY Figure 3. Types Y696VR and Y696VRM Vacuum Regulator Assemblies Description Part Number Description Part Number Spring Case Valve Spring Cast iron 2B155719042 303 Stainless Steel (standard) 0D002827022 WCC Steel 34B2157X012 316 Stainless Steel (NACE) CF8M Stainless steel 34B2157X042 or Hastelloy...
  • Page 8 Technologies, Inc. All rights reserved. 01/19. Emerson Automation Solutions The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher™ is a mark owned by Fisher Controls International LLC, a...