Troubleshooting - Graco G-Chem Series Instructions And Parts

Beam pump
Table of Contents

Advertisement

Troubleshooting

Troubleshooting
1. Follow Pressure Relief Procedure, page 12,
before checking or repairing the pump.
Problem
Air bubbles in fluid
Fluid leaking
Lever arm moving, but fluid not mov-
ing
18
2. Check all possible problems and causes before dis-
Cause
Suction line is loose
Loose fittings
Worn or damaged seals and/or pack-
ing
Pump stalled
Air in pump
Worn or damaged check valve seals Replace inlet and outlet check valves
assembling the pump.
Tighten suction line
Tighten fittings
Adjust or tighten seals and/or pack-
ing. If leak persists, replace seals
and/or packing.
Check pump for contamination
Prime pump
Solution
3A6349A

Advertisement

Table of Contents
loading

Table of Contents