STEP 10
Clean pump body as required then re-install discharge check
valve components in order shown shown
STEP 11
Thread discharge check valve bushing [A] into fluid end body
[Torque 90-100 In-lbs]
STEP 12
Re-connect secondary containment line to the system
37
STEP 13
Connect all previously installed suction and discharge lines to
the fluid end
Only properly qualified and trained personnel should be involved
in the setting up, putting into service, inspecting and repairing of
this equipment
Ensure National, Provincial/State and local codes are followed
when plumbing equipment. Failure to follow these codes can re-
sult in serious bodily injury or death
A
Typical installation shown above Please refer to the 'Installa-
tion' section of this manual for a complete item breakdown
A
CAUTION!