GENERAL SAFETY

System Startup

STEP 1
WIRING INTERFACE
Wire 24V DC power supply out to the main terminal block on the pumps front access panel, always
ensure wiring polarity is correct to prevent system damage CAUTION: System will start automatically
Model C1 pumps are equipped with COLDStart technology This technology ensures proper operation
during the winter months by temporarily increasing the motors supply current at startup When the sys-
tem is in COLD start mode 'UP' will appear on the digital display The System will automatically revert to
normal operating conditions when its warm up routine is complete [~
]
10
Minutes
If the ambient temperature is warmer than -10
C the COLDStart routine is not required To bypass the
O
routine early, press the 'UP' or 'DOWN' arrow button once to resume normal operation
STEP 2
If desired 'Strokes Per Minute' [SPM] setting is known adjust desired pump rate by pressing the UP/
DOWN stroke rate keys on the control module until desired SPM rate is displayed
If desired stroke rate is not known please refer to the next section in this manual 'Operating Instructions'
for a complete set of instructions