Name of part

Name of part
Brushless amplifier
● 50 W, 100 W
[front view]
35
21
Attachment hole
10
Power LED (PWR)
(green: when power is ON)
Alarm LED (ALM)
(red: when Trip is operation*)
connector for control signals (I/O)
connector for Communications
(SER)
connector for power input
(POWER)
connector for motor connection
(MOTOR)
5.2
Grounding
10
terminal
21
* The meaning of "trip" is that a protection circuit operates and stops.
screw
● 200 W, 400 W, 750 W
[front view]
68
Attachment hole
6.5
Power LED (PWR)
(green: when power is ON)
Alarm LED (ALM)
(red: when Trip is operation*)
connector for control signals
(I/O)
connector for Communications
(SER)
connector for motor connection
(MOTOR)
5.2
Grounding
20
terminal
Terminal for power supply input (POWER)
screw
* The meaning of "trip" is that a protection circuit operates and stops.
[side view]
105
75
[side view]
120
75
- 6 -

Installation

Install the brushless amplifier properly for preventing failure and accident.
Transport
• Use caution enough in transporting the unit to prevent injury by drop or fall, and avoid damage
to the equipment.
Storage
• Keep the unit indoors in a clean and dry place free from vibration with little change of
4.3
temperature.
• In keeping a gear head alone, direct the output shaft down.
(Otherwise, grease leaking is possible.)
Location
• Location gives great influence upon the life of brushless amplifier, therefore choose a place in
conformance with the conditions below:
(1) Indoors where the motor is not subjected to rain water and direct sun beam.
(2) Do not use the motor in corrosive atmosphere such as hydrogen sulfide, sulfurous acid,
chlorine, ammonia, sulfur, gas chloride, gas sulfide, acid, alkali, and salt, in the atmosphere
of combustible gas, or in the vicinity of flammables.
(3) Place not exposed to grinding liquid, oil mist, iron powder, and cutting particle.
(4) Well-ventilated place with little moisture, oil, or inundation, and place far from heat source
such as a furnace.
(5) Place easy to check and clean
(6) Place free from vibration
(7) Do not use the unit in an enclosed environment. Enclosing may raise the temperature of
[Unit: mm]
motor (amplifier), and shorten their life.
Environmental condition
Item
Ambient temperature
Ambient humidity
4
Storage temperature
Protection structure
Vibration
Altitude
*1 Ambient temperature is measured at a distance of 5 cm
from the product.
*2 Temperature which is acceptable for a short time, such as
during transportation, is –20 ℃ to 60 ℃ (free from freezing).
How to Install
The amplifier is a vertical placement type. Install it vertically
and provide at least 10 cm space around it for ventilation.
(1) When installing with screw
Determine the fastening torque of the fixing screw based on
the strength of the screw and material of the mounting surface,
to ensure secure and safe installation.
Example:
4
To install to steel plate with steel screw (M4): 1.35 to 1.65 N・m
[Unit: mm]
(2) When installing to DIN rail (50 W, 100 W)
The DIN rail mounting unit is available as option.
For details, refer to the Instruction Manual (Overall).
Condition
0 ℃ to 50 ℃ (free from freezing)
*1
20 to 85 % RH (free from condensation)
At normal temperature and normal humidity
Equivalent to IP20
Not greater than 5.9 m/s
(10 to 60 Hz)
2
Not greater than 1000 m
50 W
100 W
Location of fixing screw
Vertical
- 7 -
Location of fixing screw
*2
200 W
400 W
750 W