> C SER MANUAL ONTENTS ONTENTS I. I NTRODUCTION 1. Important 2. Outline of product overview 3. Classification II. S AFETY INFORMATION 1. Introduction 2. Safety symbols 3. Environmental factors 4. Safety precautions III. F EATURES IV. N OTES FOR USING THE INSTRUMENT V.
LCD panel, including red /green for eye optometry. The CSPOLA600 / CSPOLA600C can be rotated either using either a cabled or wireless remote control, or by the Essilor APH550. The chart rotation for CSPOLA600 / CSPOLA600C can be performed by either wired or wireless remote control or by external devices by control box of digital phoropter.
> I. I SER MANUAL NTRODUCTION 3. C LASSIFICATION The CSPOLA600 / CSPOLA600C is a class I medical device type B. This device is compliant with marking. Expected useful life: 7 years Date of first marking: 2013 CSPOLA600 / CSPOLA600C - Polarized visual chart system > V5 - 03-2018...
> II. S SER MANUAL AFETY INFORMATION 1. I NTRODUCTION Safety is everyone's responsibility. The safe use of this equipment largely depends on the installer, user, operator, and maintainer. It is imperative that personnel study and become familiar with this entire manual before attempting to install, use, clean, service or even just adjust this equipment and any associated accessories.
> II. S SER MANUAL AFETY INFORMATION 2. S AFETY SYMBOLS The International Electro-technical Commission (IEC) has established a set of symbols for electronic medical equipment which classify a connection or warn of any potential hazards. Save these instructions I and O on power switch represent ON and OFF respectively. This symbol identifies a safety note.
> II. S SER MANUAL AFETY INFORMATION 3. E NVIRONMENTAL FACTORS Avoid the following environments for operation or storage. Where the equipment is exposed to water vapor. Don't operate an equipment with a wet hand. Where the equipment is exposed to direct sunlight. Where the temperature changes extremely.
> II. S SER MANUAL AFETY INFORMATION 4. S AFETY PRECAUTIONS This equipment has been developed and tested in accordance with safety standards as well as national and international standards. This guarantees a very high degree of safety for this device. Under legislation currently in force, we are required to inform users expressly about the device's safety aspects.
Page 12
> III. F SER MANUAL EATURES The CSPOLA600 / CSPOLA600C system enables users to reverse all types Red / Green reverse of Red/Green chart by using the Black & White reverse button on the remote control. The CSPOLA600 / CSPOLA600C system has an animation function. This Animation function can be used for getting a child to concentrate on the chart during the sight test, making it is easier to carry out.
Page 14
> IV. N SER MANUAL OTES FOR USING THE INSTRUMENT 1. Do not hit or drop the instrument. The instrument may be damaged if it sustains a strong impact. Impact damage may prevent the product from operating properly. Handle it with care. 2.
Page 16
> V. C SER MANUAL ONFIGURATIONS The CSPOLA600 / CSPOLA600C's main components are shown below. 1. LCD screen: for displaying charts (Optotype) 2. IR Cover: for receiving signals from the remote control 3. LED Lamp 4. Wall mount hole 5. Power switch: for powering the unit ON and OFF 6.
> VI. I SER MANUAL NSTALLATION 1. V (LCD IEWING DISTANCE DISPLAY POSITION Since it is possible to operate the unit by remote control, the operator can examine the patient while ensuring that the charts are changing properly. The product must be set up so that the centre of the LCD screen is level with the patient's eyes, ensuring that it is not affected by light.
> VII. T SER MANUAL EST METHOD IVISION ESCRIPTION EST METHOD 1. Show binocular test types to a patient. The test is for 2. Let a patient wear Red/Green glasses (right eye = red synchronizing the filter, left eye = green filter). Orthoptic test - (Binocular visual function with 3.
Page 21
> VII. T SER MANUAL EST METHOD IVISION ESCRIPTION EST METHOD 1. Show aniseikonia test type. 2. Let a patient wear Red/Green glasses (right eye = red filter, left eye = green filter). The patient sees fixation target and “]” in a right eye and fixation target and “[”...
Page 22
> VII. T SER MANUAL EST METHOD IVISION ESCRIPTION EST METHOD Patient's Phoria Method visual status Add B.O prism until a vertical line ⓐ Esophoria can come to the center of a horizontal line. This test is for testing Add B.I prism until a vertical line can horizontal/verti ⓑ...
Page 23
> VII. T SER MANUAL EST METHOD IVISION ESCRIPTION EST METHOD 1. Show Schober's test type to a patient. 2. Let a patient wear Red/Green glasses (right eye = red filter, left eye = green filter). The patient sees « »...
> VIII. R SER MANUAL EMOTE CONTROL FUNCTION 2. S LIDE FUNCTION 1. Additional function can be selected after slide button press. 2. Charts can be changed for quality improvement without notice. CSPOLA600 / CSPOLA600C - Polarized visual chart system > V5 - 03-2018...
Page 28
> IX. H SER MANUAL OW TO RECHARGE A REMOTE CONTROL Remote control can be rechargeable by the USB adapter. CSPOLA600 / CSPOLA600C - Polarized visual chart system > V5 - 03-2018...
> X. U CSPOLA600 / CSPOLA600C SER MANUAL PGRADING A SYSTEM Insert the USB upgrade key. Power up the unit. > It will be upgraded automatically. How to use USB slide mode: Create a folder on the USB key. Name the folder "Slide". Save the images you want in JPEG or PNG format.
Page 32
> XI. S SER MANUAL PECIFICATIONS LCD type 24 Inch Wuxga TFT LCD / optical polarizing glass type Resolution 1920 x 1080 pixels Chart window size (H) 298.89 x (W) 531.36 mm Brightness Max 300 cd / m Snellen, Landolt, English, Korean, Russian, Japanese, Numeral, Children Mask (Horizontal, Vertical, Single Optotype) Special Chart chart (Separate polarization), Amsler grid, Color Blindness,...
> XII. C SER MANUAL OMPONENT LIST 1. S TANDARD ACCESSORIES • Main body (LCD chart) • Remote control • Wall mounting bracket • Power adapter • Power supply ref BPM060S12F25) • USB adapter for remote control recharge • USB cable for remoter control •...
Page 36
> XIII. S SER MANUAL ERVICE INFORMATION If there are any problems with the product, please follow the below steps. Turn off the power. Remove the power cable connected to the equipment. Connect the power adapter to the equipment and turn on the power. Check that the equipment operates properly with the remote control.
Page 37
Essilor Instruments USA 8600 W. Catalpa Avenue, Suite 703 Chicago, IL 60656 Phone: 855.393.4647 Email: info@essilorinstrumentsusa.com www.essilorinstrumentsusa.com...