Ruijie Networks reserves all copyrights of this document. Any reproduction, excerption, backup, modification, transmission, translation or commercial use of this document or any portion of this document, in any form or by any means, without the prior written consent of Ruijie Networks is prohibited. Exemption Statement This document is provided “as is”.
It is intended for the users who have some experience in installing and maintaining network hardware. At the same time, it is assumed that the users are already familiar with the related terms and concepts. Obtaining Technical Assistance Ruijie Networks Website: https://www.ruijienetworks.com/ Technical Support Website: https://ruijienetworks.com/support...
Ruijie WS6024, the next-generation intelligent wireless controller, features high performance, high security, multiple services and ease of use to meet the needs of the current networks. The RG-WS6024 series wireless controller provides the integrated PoE/PoE+ service, various WLAN access control and unified wired and wireless network management. It is greatly ideal for small and medium sized enterprises and general education industry, providing high-speed, high-efficiency, secure and intelligent access solutions.
Page 5
Rated current range: 3.5A to 7A Frequency range: 50/60 Hz HVDC Rated voltage range: 192V to 290V Rated current range: 2.5A to 3.5A RG-PA1150P-F Rated voltage range: 100V to 240V Frequency range: 50/60 Hz Rated current: 10A HVDC Rated voltage range: 192V to 290V Rated current: 10A M5000E-DC500P (DC) Rated voltage range: -72V to -36V...
Weight 5.8 kg (with package) The RG-WS6024 wireless controller is a class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures. Product Appearance On the front panel, the RG-WS6024 wireless controller provides 24 10/100/1000Base-T Ethernet ports, 2 GE SFP fiber/copper combo ports, 2 10G SFP+ ports and 1 Console port.
Figure 1-3 Back Panel of RG-WS6024 Note: 1. Expansion module 1 slot 4. Power module 2 slot 2. Expansion module 2 slot 5. Grounding connector 3. Power module 1 slot Power Supply The RG-WS6024 supports two power modules with AC or DC input. For the detailed power specification, see the following tables.
Page 8
Power Cord Dimensions 195.4 mm x 90 mm x 40 mm(connecting finger and handle excluded) (W x D x H) 224.5 mm x 90 mm x 40mm (connecting finger and handle included) 1.6 kg Weight Model RG-M5000E-DC500P RG-WS6024 Platform Maximum Input -72V to -36V Voltage Range...
Rated Voltage 240V 100V to240V, 50/60Hz Range Maximum Input 192V to 290V 90V to 264V, 50/60Hz Voltage Range Single power supply: 740 W PoE Power Dual power supplies: 1480 W Hot Swapping Supported Redundant Power Supplies 54V: -57V to -60V Over-Voltage Protection 12V: 14V to 16V...
Page 10
LEDs Panel Identification State Meaning The wireless controller is not receiving power. The system is being initialized. Blinking green Continuous blinking indicates errors. Solid green The wireless controller is operational. System status LED Status Temperature warning Solid yellow Check the working environment of the wireless controller immediately.
Page 11
The power module is in place but the AC power Solid red chord or wireless controller is abnormal. Solid green The power supply is operational. Solid green Indicates the switching state. PoE status LED Solid yellow Indicates the PoE state. The port is not connected.
2 Preparation for Installation 2.1 Safety Suggestions To avoid personal injury and equipment damage, please carefully read the safety suggestions before you install the RG-WS6024 series wireless controller. The following safety suggestions do not cover all possible dangers. 2.1.1 Installation ...
2.2.2 Temperature and Humidity To ensure the normal operation and prolong the service life of RG-WS6024 series wireless controller, you should keep proper temperature and humidity in the equipment room. If the equipment room has temperature and humidity that do not meet the requirements for a long time, the equipment may be damaged.
Page 14
30 minutes every day. 2.2.4 Grounding A good grounding system is the basis for the stable and reliable operation of the RG-WS6024 series wireless controller. It is the chief condition to prevent lightning stroke and resist interference. Please carefully check the grounding conditions...
Page 15
All the above constitute the comprehensive grounding requirements. The resistance of earth wires should be less than 1 ohm. The back plane of RG-WS6024 series wireless controller is reserved with one grounding pole, as shown in Figure 2-5.
Page 16
wireless controller to the lightning line bank. This can help to prevent the current of high-voltage lightning from passing the wireless controller directly through the mains supply cable to a certain extent. The lightning line banks are not provided and should be purchased by users as required. For the usage of lightning line banks, refer to their related manuals.
3 Product Installation Please ensure that you have carefully read Chapter 2. Make sure that the requirements set forth in Chapter 2 have been met. 3.1 Installation Flowchart 3.2 Confirmations before Installation Before installation, please confirm the following points: Whether ventilation requirements are met for the wireless controller ...
Page 18
Do not place any articles on the RG-WS6024 series wireless controller. Reserve a spacing of at least 10 cm around the chassis for good ventilation. Do not stack the devices.
Page 19
Use the supplied M6 screws and cage nuts to securely attach the mounting brackets to the rack, as shown in Figure 3-3. Figure 3-3 3.3.2 Mounting the Wireless controller on the Wall The RG-WS6024series wireless controller can be mounted on the wall, as shown in the following figure. Attach the mounting brackets to the wireless controller with the supplied screws, as shown in Figure 3-4.
Page 20
Use the expansion screws to securely attach the mounting brackets on the wall, as shown in Figure 3-5. Figure 3-4 Attaching the Wireless Controller on the Wall 3.3.3 Mounting the Wireless controller on a Table Attach the four rubber feet to the recessed areas on the bottom of the wireless controller, as shown in Figure 3-6. Figure 3-6 Attaching the Rubber Feet to the Recessed Areas...
Place the wireless controller on the table, as shown in Figure 3-7. Figure 3-7 Mounting the Wireless Controller on the Table The device must be installed and operated in the place that can restrict its movement. 3.4 Checking after Installation Before checking the installation, switch off the power supply so as to avoid any personal injury or damage to the component due to connection errors.
4 System Debugging 4.1 Establishing the Debugging Environment Establishing the Debugging Environment Connect the PC to the console port of the wireless controller through the console cable, as shown in Figure 4-1. Figure 4-1 Schematic Diagram of the Configuration Environment Connecting the Console Cable Step 1: Connect the end of the console cable with DB-9 jack to the serial port of the PC.
Page 23
Enter the name of the new connection and click OK, the interface as shown in Figure 4-3 is displayed. Choose the serial port used currently in the column [use when connecting]. Figure 4-3 After choosing the serial port, click OK to display the serial port parameter setting interface, set the baud rate to 9600, data bit to 8, parity check to none, stop bit to 1 and flow control to none.
After setting the parameters, click OK to enter the hyper terminal interface. 4.2 Startup Check 4.2.1 Checking before the Device is Powered on The wireless controller is fully grounded. The power cable is correctly connected. The power supply voltage complies with the requirement of the wireless controller. ...
5.2 Troubleshooting Common Faults Symptom Possible Causes Solution Forgetting A password is manually configured but Please contact Ruijie Networks Customer Service management interface it is forgotten. Department for technical support. login password The status indicator is The power supply module does not...
Page 26
clean the dust on the cabinet and reinforce the refrigeration effect. Power alarm: the power module problem may be: 1) The power module is in place but no power cord is connected. Please power on the module or remove the unused power module. 2) The power module is faulty.
Page 27
AppendixA Connectors and Connection Media 1000BASE-T/100BASE-TX/10BASE-T Ports The 1000BASE-T/100BASE-TX/10BASE-T is a port that supports adaptation of three rates, and automatic MDI/MDIX Crossover at these three rates. The 1000BASE-T complies with IEEE 802.3ab, and uses the cable of 100-ohm Category-5 or Supper Category-5 UTP or STP, which can be up to 100 m.
Optical Fiber Connection For the optical fiber ports, select single-mode or multiple-mode optical fibers for connection according to the fiber module connected. The connection schematic diagram is shown in Figure A-4: Figure A-4 Optical Fiber Connections...
Page 29
AppendixB Mini-GBIC and SPF+ Module SFP module (Mini-GBIC module) and 10G SFP+ module are available to address the requirements of interface types of wireless controller modules. You can select the Mini-GBIC or SFP+ module to suit your specific needs. Besides the following modules, the 10G SFP+ module also supports the Mini-GBIC-GT module.
Page 30
For the optical module with transmission distance exceeding 40 km and more, one on-line optical attenuator should be added on the link to avoid the overload of the optical receiver when short single-mode optical fibers are used. Table B-3 Specifications of SFP BIDI Optical Module Pairs Rate/Distance Module Pairs FE-SFP-LX20-SM1310-BIDI...
Page 31
XG-SFP-LR- 1310 10km -8.2 -10.3 SM1310 interface) XG-SFP-ER- 1550 40km -4.7 -11.3 SM1550 interface) XG-SFP-ZR- 1550 80km SM1550 interface) The existing 10G SFP+ copper modules: Copper Module Connector Conductor Wire Data Model Cable Type Type Diameter (AWG) Rate(Gb/s) (Yes/No) Length(m) XG-SFP-CU1M Passive SFP+...
Page 32
AppendixC Lightning Protection Installing AC Power Arrester (lightning protection cable row) The external lightning protection cable row shall be used on the AC power port to prevent the wireless controller from being struck by lightning when the AC power cable is introduced from the outdoor and directly connected to the power port of the wireless controller.
Page 33
During the wireless controller usage, the Ethernet port arrester shall be connected to the wireless controller to prevent the wireless controller damage by lightning before the outdoor network cable connects to the wireless controller. Tools: Cross or straight screwdriver, Multimeter, Diagonal pliers Installation Steps: Tear one side of the protection paper for the double-sided adhesive tape and paste the tape to the framework of the Ethernet port arrester.
Page 34
You may pay attention to the following conditions during the actual installation to avoid influencing the performance of the Ethernet port arrester: Reversed direction of the arrester installation. You shall connect the external network cable to the “IN” end and ...
Page 35
AppendixD Cabling Recommendations in Installation When RG-WS6024 series wireless controller is installed in standard 19-inch cabinets, the cables are tied in the binding rack on the cabinet by the cabling rack, and top cabling or bottom cabling is adopted according to the actual situation in the equipment room.
Page 36
Cables of different types (such as power cords, signal cables, and grounding cables) should be separated in cabling and bundling. When they are close, crossover cabling can be adopted. In the case of parallel cabling, power cords and signal cables should maintain a space equal to or greater than 30 mm. ...
Page 37
Figure D-3 Bundling Up Cables (3) Cables not to be assembled or remaining parts of cables should be folded and placed in a proper position of the cabinet or cabling slot. The proper position indicates a position that will not affect device running or cause device damage or cable damage during commissioning.
Page 38
The hard power cable should be fastened by the terminal connection area to prevent stress. Do not use self-tapping screws to fasten terminals. Power cables of the same type and in the same cabling direction should be bundled up into cable bunches, with cables in cable bunches clean and straight.
Page 39
AppendixE Site Selection The machine room should be at least 5km away from the heavy pollution source such as the smelter, coal mine and thermal power plant, 3.7km away from the medium pollution source such as the chemical industry, rubber industry and electroplating industry, and 2km away from the light pollution source such as the food manufacturer and leather plant.
Need help?
Do you have a question about the RG-WS6024 Series and is the answer not in the manual?
Questions and answers