SMC Sierra Monitor FieldServer FS-8704-23 Driver Manual

Energywise endpoint

Advertisement

Quick Links

FieldServer
FS-8704-23 EnergyWise Endpoint
Driver Manual
(Supplement to the FieldServer Instruction Manual)
APPLICABILITY & EFFECTIVITY
Effective for all systems manufactured after December 2017.
Driver Version:
1.01
Document Revision: 2.B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FieldServer FS-8704-23 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SMC Sierra Monitor FieldServer FS-8704-23

  • Page 1 FieldServer FS-8704-23 EnergyWise Endpoint Driver Manual (Supplement to the FieldServer Instruction Manual) APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after December 2017. Driver Version: 1.01 Document Revision: 2.B...
  • Page 2 EnergyWise Endpoint Driver Manual Technical Support Please call us for any technical support needs related to the FieldServer product. Sierra Monitor Corporation 1991 Tarob Court Milpitas, CA 95035 Website: www.sierramonitor.com U.S. Support Information: +1 408 964-4443 +1 800 727-4377 Email: support@sierramonitor.com EMEA Support Information: +44 2033 1813 41...
  • Page 3: Table Of Contents

    EnergyWise Endpoint Driver Manual TABLE OF CONTENTS EnergyWise Endpoint Description ..................... 4 Driver Scope of Supply ........................4 Supplied by Sierra Monitor Corporation ..................4 Provided by the Supplier of 3 Party Equipment................4 2.2.1 Required 3 Party Hardware ....................4 2.2.2 Required 3 Party Configuration .....................
  • Page 4: Energywise Endpoint Description

    EnergyWise Endpoint Driver Manual ENERGYWISE ENDPOINT DESCRIPTION The EnergyWise Endpoint driver allows the FieldServer to participate on an EnergyWise domain as a Parent Node with multiple Child Nodes. The FieldServer gateway acts as a Parent node on the EnergyWise domain and a number of Child Nodes can be configured to read third party server devices such as Power Meters on Modbus or HVAC controllers on LonWorks.
  • Page 5: Hardware Connections

    EnergyWise Endpoint Driver Manual HARDWARE CONNECTIONS The FieldServer is connected to an EnergyWise capable switch as shown in the connection drawing. Configure the EnergyWise switch according to the manufacturer’s instructions. Typically, this will involve Appendix A.1 enabling the EnergyWise domain and specifying a Shared Secret code. Refer to for a typical CLI session on a Cisco EnergyWise switch.
  • Page 6: Data Array Parameters

    EnergyWise Endpoint Driver Manual DATA ARRAY PARAMETERS Data Arrays are “protocol neutral” data buffers for storage of data to be passed between protocols. It is necessary to declare the data format of each of the Data Arrays to facilitate correct storage of the relevant data.
  • Page 7: Configuring The Fieldserver As A Energywise Endpoint Client

    EnergyWise Endpoint Driver Manual CONFIGURING THE FIELDSERVER AS A ENERGYWISE ENDPOINT CLIENT Client Configuration is not applicable for the EnergyWise Endpoint Driver. Refer to FS-8704-24 EnergyWise Management API Driver for Client operation. Page 7 of 11...
  • Page 8: Configuring The Fieldserver As A Energywise Endpoint Server

    EnergyWise Endpoint Driver Manual CONFIGURING THE FIELDSERVER AS A ENERGYWISE ENDPOINT SERVER For detailed information on FieldServer configuration, refer to the FieldServer Configuration Manual. The information that follows describes how to expand upon the factory defaults provided in the configuration files included with the FieldServer (see “.csv”...
  • Page 9: Server Side Map Descriptor Parameters

    EnergyWise Endpoint Driver Manual Node_Device_Type Device type connected to the Node. Any ASCII string – Node_Role Role definition for the Node. max 255 characters Specify one or more keywords which are used to identify the Node when the EnergyWise query command is executed.
  • Page 10: Map Descriptor Example

    EnergyWise Endpoint Driver Manual Importance Value for the Device, 100 most important, 1 least important. EnergyWise query results can be MD_Importance* 1 to 100 executed to operate on any Node with an importance less than the specified importance. Importance Value for Node with 100 the most important keyword.
  • Page 11: Appendix A Reference

    EnergyWise Endpoint Driver Manual APPENDIX A REFERENCE Appendix A.1 EnergyWise Endpoint Setup on Cisco Router The commands can be used to set up the domain and secret (using domain = fst and secret = pass) as per Section 6.2. • Switch>...

Table of Contents