OPTIONAL ADD-ONS

PRE-FILTER (OPTIONAL COMPONENT)
Considerations:
Account for a minimum of 2" clearance at the bottom for future filter replacements.
Location of Pre-filter and Inline Ball Valve diagram is on page 11.
• Turn off your source water.
• Find a location where you can drive the screws for the bracket into the wall that will reach both your
source water line and your Sterisil® Ac+ System source line.
• If you have a Sterisil® Booster Pump, the Pre-filter Kit will go before the Booster Pump on the source
water line. (Reference pg. 11)
• Use a 15/64" to ¼" drill bit to drill holes in which to put the anchors.
• Drive the #10 screws into the anchors through the holes in the metal mounting bracket.
• Use the thread tape to cover the threaded end of the push-in fitting adapters.
• Twist the two quick connect fitting adapters into the two holes on the lid of the filter housing.
• Attach the filter housing to the mounting bracket using the screws provided.
• With towels ready to catch any leaking water, make a clean square cut on the source line using a
tube cutter or sharp knife. Note: If the cut is jagged, the connection will not be secure and may leak.
At the "IN" on the Pre-filter lid, insert the source water line. At the "OUT" on the Pre-filter head, insert
the water line to the system. Make sure the tubing is fully connected. You should feel it lock into
place, and you should not be able to pull it loose or have it slip out.
• Make a cut on the incoming line, and install your inline ball valve with the valve in the open position.
• Turn your source water back on.
• Check for any leaks. If there are any leaks, confirm all connections are attached securely.
• Turn your source water back off. Place one of the sediment filters in the housing, and turn your
source water back on.
CHANGING THE FILTER
Please consult with your Sterisil Dental Water Compliance Specialist to confirm your replacement
interval. Mark your calendar for the specific interval.
• Close the inline ball valves before and after the housing.
• Purge the pressure from the filter housing by depressing the red button on the top of the lid.
• Unscrew the water reservoir lid to access and replace the micron filter inside.
• Reassemble and open the inline and source water valves to restore flow to the system.
• Visually confirm water is flowing freely.