Siemens SIMATIC PCS 7 Operation And Maintenance page 42

Process control system pcs 7 compendium part d
Hide thumbs Also See for SIMATIC PCS 7:
Table of Contents

Advertisement

Replacing hardware
4.3 Procedure for replacing hardware
Procedure
The exact procedure for a specific component is provided in its accompanying manual. The
table below provides information about the relevant components and associated manuals.
Component
Module of an ET 200SP HA
Interface module of ET 200SP
HA
ET 200M interface in a non-
redundant system
ET 200M interface in a redun-
dant system
ET 200M module
ET 200M redundant module
ET 200M bus module
Connection of DP/PA link and
Y link
ET 200iSP interface
ET 200iSP interface in a re-
dundant system
42
Manual/section
Manual "SIMATIC ET 200SP ET 200SP
HA Distributed I/O System"
"Maintenance"
Manual "SIMATIC ET 200SP HA Inter-
face Module IM 155-6 PN HA
(6DL1155-6AU00-0PM0)"
"Maintenance"
Manual "SIMATIC Distributed I/O De-
vice ET 200M"
, section "Maintenance
3)
and service"
Manual "SIMATIC Distributed I/O De-
vice ET 200M"
, section "Maintenance
3)
and service"
Manual "SIMATIC Fault-tolerant Sys-
tems S7-400H"
, section "Failure and
5)
replacement of components during
operation"
Manual "SIMATIC Distributed I/O De-
vice ET 200M"
, section "Maintenance
3)
and service"
Manual "SIMATIC Distributed I/O De-
vice ET 200M"
, section "Maintenance
3)
and service"
Manual "SIMATIC Bus Links DP/PA
Coupler, Active Field Distributors,
DP/PA Link and Y Link"
, section
6)
"Maintenance and service"
Manual "SIMATIC Distributed I/O ET
200iSP"
, section "Replacing the inter-
7)
face module"
Note
, section
1)
, section
2)
You can find possible combinations of bus
module, interface module and configuration
under "New PROFIBUS Interface Modules for
ET 200M, DP/PA Link and Y Link"
Please note that the startup time following in-
stallation of the module is longer for fail-safe
modules than for standard ones.
Active bus modules can only be installed on an
IM 153–2 if the power supply is interrupted.
You can find possible combinations of bus
module, interface module and configuration
under "New PROFIBUS Interface Modules for
ET 200M, DP/PA Link and Y Link"
You can find possible combinations of bus
module, interface module and configuration
under "New PROFIBUS Interface Modules for
ET 200M, DP/PA Link and Y Link"
Setting and altering the address may require
deletion of the non-volatile parameters on the
interface. This is only possible by shutting off
the power supply. This step may not be possible
in a redundant system.
Set the address of the IM 152 on the module in
advance. This way you can avoid having to shut
down the station. The IM will start up with the
correct address.
Compendium Part D - Operation and Maintenance (V9.0)