Panasonic VBHN330SA17E General Installation Manual page 5

Photovoltaic module
Hide thumbs Also See for VBHN330SA17E:
Table of Contents

Advertisement

Front
Note) A module is installed using 4 points, symmetrical mounting
within setting range (Black arrows).
Table 1-3. Mount location and Load Resistance
Mounting location range
(mm)
Load Resistance (Positive Load)
Load Resistance (Negative Load)
Note) Load Resistance shown above is UL Test-Load.
Design load is a value obtained by multiplying the above value by two thirds.
Side
Figure 1. Module Dimension
(VBHN330SA17E)
L1
0
L2
450
S1
-
S2
-
50 psf
(2400 Pa)
50 psf
(2400 Pa)
5
Backside
230
230
380
345
-
-
-
-
112 psf
112 psf
(5400 Pa)
(5400 Pa)
91 psf
112 psf
(4400 Pa)
(5400 Pa)
Dimension in mm
Section A-A
Section B-B
-
-
0
250
50 psf
(2400 Pa)
50 psf
(2400 Pa)