Fujitsu ASYG09KXCA Service Manual page 8

Split type room air conditioner wall mounted type
Hide thumbs Also See for ASYG09KXCA:
Table of Contents

Advertisement

TO INDOOR UNIT
TERMINAL
L
1
N
2
SERIAL
3
POWER SOURCE
4
AC230V
50Hz
5
POWER EARTH
WIRE w/TERMINAL (CORE)
1015#22
GREEN
EMI FILTER
ZCAT1518-0730
1 TURN
P1
Thermistor Characteristics.
Temperature
( 0
)
( 20
)
( 30
Thermistor
16.1 k
6.1 k
4.0 k
Thermistor ( Pipe temp. )
1.1 V
2.2 V
2.8 V
168.6 k
62.6 k
40.0 k
Thermistor ( Discharge temp. )
0.4 V
0.9 V
1.2 V
P5
Thermistor Characteristics.
Temperature
( 0
)
( 20
)
( 30
Thermistor
35.2 k
12.6 k
8.0 k
Thermistor ( Outdoor temp. )
2.6 V
3.8 V
4.1 V
2016.08.01
EMI FILTER
EMI FILTER
TRCB-25-15-12
ZCAT3035-1330
3 TURNS
1 TURN
UL1015
AWG20
W103
BLACK
B
UL1015
AWG20
W104
WHITE
B
UL1015
AWG20
W70
RED
B
UL1015
AWG14
W100
BLACK
B
UL1015
AWG14
W101
WHITE
B
UL1015
AWG16
W102
GREEN
B
FRAME
FRAME
BLACK
1
THERMISTOR ( PIPE TEMP. )
2
BLACK
)
3
BLACK
THERMISTOR ( DISCHARGE TEMP. )
4
BLACK
1
BLACK
THERMISTOR ( OUTDOOR TEMP. )
2
)
3
BLACK
INVERTER ASSEMBLY
AOYG09KXCA : EZ-0169HUE
AOYG12KXCA : EZ-016AHUE
MAIN PCB
AOYG09KXCA : K15DC-1600HUE-C1
AOYG12KXCA : K15DC-1601HUE-C1
P1
B04B-PLIRK-1
RED
P5
B03B-PLISK-1
WHITE
7
EMI FILTER
KRFC-13
1 TURN
UL3271
AWG16
W400
RED
U
B
UL3271
AWG16
W401
WHITE
CM
V
B
UL3271
AWG16
W402
BLACK
W
B
P60
1
BLACK
4-WAY VALVE COIL
B2P3-VH-B-E
2
BLACK
DC Resistance 2070
BLUE
Cooling ( 1.5sec )
DC V ( 1+, 2- )
Heating ( 1.5sec )
DC V ( 1-, 2+ )
DC340V
1
RED
2
DC15V-1
3
4
BLACK
FM
DC FAN MOTOR
5
WHITE
P650
6
YELLOW
B5 ( 7-2.3 ) B-XASK-1-A
7
BROWN
WHITE
DC12V
1
RED
2
P30
BLUE
B05B-PLISK-1
3
M
ORANGE
EXPANSION VALVE COIL
WHITE
4
YELLOW
5
WHITE
P20
1
RED
PRESSURE SWITCH
B03B-XNISK-A-1
2
RED
WHITE
Compressor
Winding Resistance
U-V
V-W
( 20
)
U-W
COMPRESSOR
10%
(20
)
P650
DC Fan motor
Terminal
Lead wire
Pin No.
Function of terminal
code
color
1
Vm
Motor power voltage input
Red
2
3
4
GND
GND
Black
5
Vcc
Control power voltage input
White
6
Vsp
Speed control voltage input
Yellow
7
FG
Revolution pulse output
Brown
P30 Expansion valve coil
Recommended drive condition
unipolar draive, 1-2 phase excitation.
1(Red) - 2(Blue)
Coil resistance
1(Red) - 3(Orange)
46.0
1(Red) - 4(Yellow)
( 20
)
1(Red) - 5(White)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aoyg09kxcaAsyg12kxcaAoyg12kxca

Table of Contents