Install The Gun Onto The Manifold - Graco 236685 Instructions And Parts List

Air spray gun
Hide thumbs Also See for 236685:
Table of Contents

Advertisement


Tighten the screws (24) to 18 in-lbs (2 NSm) maximum (about half
turn past snug), using the wrench (77) provided.

Install the nut (46) flush to the end of the piston rod (23g).

24

33
26
13
Fig. 32

Install the Gun onto the Manifold

1. Make sure the gaskets (108, 121), and spring
(105) are in place on the manifold (101). See Fig.
33. Inspect the parts for damage and replace them
as needed.
2. Secure the gun (B) to the manifold (101) by tight-
ening the three screws (106) with the ball end
wrench (77–not shown).
3. Secure the gun (B) to the mounting bracket (102)
by tightening the screw (21) with the ball end
wrench (77).
Service

Adjust the nut (36) to create 0.125 in. (3 mm) gap between the
actuator arm (19) and the nut.

Make sure the entire fluid tube (33) is clear of the actuator
arm (19).
27a
27
20
11
Fig. 33
29

36
23g
19

46
121
108
105
B
21
4
43
03901A
106
101
102
03218
308442
37