Settings; Opening/Closing Delay Time Settings; Single Gate Leaf Operation Setting; Operation Mode Setting - Chamberlain LA350 Installation Manual

Swing gate operator
Table of Contents

Advertisement

Available languages

Available languages

SETTINGS

Opening/Closing Delay Time Setting
Factory default is set at 2 seconds.
The Open/Closing Delay times can be individually set
from 1-4 seconds.
Opening Delay:
1 OFF and 2 OFF = 1 second
1 ON and 2 OFF = 2 seconds
1 OFF and 2 ON = 3 seconds
1 ON and 2 ON = 4 seconds
The minimum delay time is 1 second.
Closing Delay:
3 OFF and 4 OFF = 1 second
3 ON and 4 OFF = 2 seconds
3 OFF and 4 ON = 3 seconds
3 ON and 4 ON = 4 seconds
The minimum delay time is 1 second.

Single Gate Leaf Operation Setting

5 ON = Only MOTO1 operator is available.
5 OFF = Both MOTO1 and MOTO2 operators are available.

Operation Mode Setting

6 ON = The operation mode is :
OPEN-STOP-CLOSE-OPEN
6 OFF = The operation mode is:
OPEN-STOP-CLOSE-STOP-OPEN
Auto Close Time Setting
Factory default for this function is OFF. The time can be set
from 0-105 seconds.
1 = 15s
2 = 30s
If all the DIP switches are set to the ON position, the auto
closing time is 105 seconds. If all the DIP switches are set
to the OFF position, the gate leaf will not close automatically.
3 = 60s
20
1 2 3 4 5 6 7 8
S1
Opening Delay set for 4 seconds
1 2 3 4 5 6 7 8
S1
Closing Delay set for 4 seconds
1 2 3 4 5 6 7 8
S1
MOTO1 only
1 2 3 4 5 6 7 8
S1
OPEN - STOP - CLOSE - OPEN
1 2 3 4 5 6 7 8
S1
1 2 3 4
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
S2
OFF

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents