DeLonghi EX Series Manual page 8

Hide thumbs Also See for EX Series:
Table of Contents

Advertisement

Check the plate for the type of refrigerant gas used
in your appliance.
Specific information regarding appliances with
R410A refrigerant gas
R410 is a refrigerant gas that complies with EC ecology regula-
tions. Do not puncture the refrigerant circuit on the appliance.
Environmental information: This unit contains fluorinated
greenhouse gases covered by the Kyoto Protocol. Maintenance
and disposal must only be performed by qualified personnel
(R410A, GWP=2088).
Specific information regarding appliances with
R290 refrigerant gas
Thoroughly read all of the warnings.
When defrosting and cleaning the appliance, do not
use any tools other than those recommended by the
manufacturing company.
The appliance must be placed in an area without any
continuous sources of ignition (for example: open flames,
gas or electrical appliances in operation).
Do not puncture and do not burn.
Refrigerant gases can be odourless.
The appliance must be installed, used and stored in an area
2
that is greater than 15 m
.
This appliance contains 300 g of R290 refrigerant gas.
R290 is a refrigerant gas that complies with the European
directives on the environment. Do not puncture any part of
the refrigerant circuit.
If the appliance is installed, operated or stored in a non-
ventilated area, the room must be designed to prevent the
accumulation of refrigerant leaks resulting in a risk of fire
or explosion due to ignition of the refrigerant caused by
electric heaters, stoves, or other sources of ignition.
The appliance must be stored in such a way as to prevent
mechanical failure.
Individuals who operate or work on the refrigerant
circuit must have the appropriate certification issued by
an accredited organisation that ensures competence in
handling refrigerants according to a specific evaluation
recognized by associations in the industry.
Repairs must be performed based on the recommendations
from the manufacturing company.
Maintenance and repairs that require the assistance of
other qualified personnel must be performed under
the supervision of an individual specified in the use of
flammable refrigerants.
WARRANTY AND TECHNICAL ASSISTANCE
Warranty and technical assistance conditions are indicated in the
documentation provided with your appliance.
TECHNICAL DATA
Power supply
Max absorbed power
in air conditioning
Refrigerant
Cooling capacity
Limit operating conditions:
Temperature in the room
being cooled
Disposal of the appliance
The appliance must not be disposed of with household
waste but taken to an authorised waste separation and
recycling centre.
Electrical Connection
Before plugging into the mains, check the following:
the mains voltage is the same as that indicated on the plate
on the back of the appliance;
the socket and electrical line are sized to support the load
required;
the socket is the proper type for the plug, otherwise, re-
place the socket;
the socket is connected to an efficient earthing system. The
manufacturer is not responsible in the event of non-com-
pliance with these injury prevention standards.
The power cable must only be replaced by special-
ised technicians.
7
See characteristic plate
"
"
"
21 ÷ 35°C

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pac ex120

Table of Contents