Now with enhanced sensitivity
Warnings
Ensure you read this user guide before installing and
using the product.
Babysense is a high quality, high sensi�vity electronic
device, which must be handled with care:
• Do not handle roughly, drop or throw.
• Follow the installa�on instruc�on carefully to ensure
the device is installed securely and correctly.
• Babysense is not a toy. Do not allow children of any
age to play with it.
• Do not put any addi�onal baby or pet in the bed.
Babysense cannot be used for two infants in one bed.
• Do not operate the unit in the presence of
electromagne�c interference.
• Portable and mobile RF communica�ons equipment
may effect opera�on of this device.
• You must undertake the performance test daily and
every �me you move the monitor, change bedding or
relocate crib/bed posi�on (as set out on page 3).
• Do not operate vaporizer or ven�lator directly towards
the bed.
• To avoid possible danger from sensor cords, ensure
that excess cords are pulled back under the ma�ress,
secured with the included cable �e and are not visible
or reachable.
• Install 4 new and iden�cal size AA 1.5 volt ba�eries,
preferably alkaline.
• IMPORTANT: It is strongly advised that parents and
caregivers learn how to give first aid.
• Please remove ba�eries if the device is not in use for a
long �me (more than 3 months).
• If you have any problems with this device, such as
se�ng up, maintaining or using, please
contact the manufacturer's service personnel. Also,
please report to the manufacturer if any unexpected
opera�on or events occur.
• Do not use the equipment if you no�ce a change in the
system's performance, if the system is damaged, or if
any of its components are worn or frayed.
• The equipment should not be used adjacent to or
stacked with other equipment. If adjacent or stacked
use is necessary, the equipment should be observed to
verify normal opera�on in the configura�on in which it
is used.
Please note
Babysense monitors and alerts, but cannot prevent
cessa�on of breathing. The responsibility for applying first
aid rests on caretakers. The Babysense senses breathing
movements and mo�on only, and cannot monitor other
occurrences. The purpose of the device is to alert when
stopping or slowing of breathing and movement occur.
Babysense is a unique safety system which has helped save
infants, giving parents (or caretakers) assurance, by
enabling interven�on in the event of irregular breathing
movement or distress, before it becomes cri�cal. There are
a number of cau�onary steps, which are interna�onally
recommended for SAFE SLEEPING:
User Guide
7
* Always lay baby to sleep on his or her back.
* Refrain from smoking near or around baby.
* Avoid over-hea�ng of baby's surrounding.
* Do not leave any objects near your baby that can
cause suffoca�on.
Babysense is an addi�on to these precau�ons.
Babysense 7 is a home breathing movement monitor for
infants up to one year of age, and is not to be used with
high-risk infants requiring constant medical supervision.
Medically trained staff such as nurses, or non-medically
trained users such as parents or caregivers may use the
Babysense. Babysense 7 is intended for home use.
Babysense con�nually detects baby's mo�on and
breathing movements, and will set off a sound and visual
alarm if movement stops for 20 seconds or if the
breathing rate slows to below 10 breaths per minute.
The system's non-touch sensor pads under the ma�ress
monitor baby's movement without restraining him.
1. For inser�ng the ba�eries, remove the ba�ery cover
by inser�ng a wide flat screw driver into the opening
recess (see illustra�on 6). Insert, in accordance with the
markings, 4 new and iden�cal size AA 1.5 volt ba�eries,
preferably alkaline and close cover.
Note: Please dispose of used ba�eries in accordance
with local waste regula�ons.
2. Place control unit holder on the base of the crib or
bed and in between two bars as shown in illustra�on 1.
3. Sensor pad installa�on:
• When using for infant not yet able to crawl, place one
sensor pad as shown in illustra�on 2. Make sure the
sensor is placed underneath baby's loca�on in crib.
• When baby begins to crawl, and is able to move onto
areas not "covered" by a single sensor pad, a�ach the
second sensor and place the two sensors as shown in
illustra�on 2.
PLEASE NOTE: The sensors shall be placed with the
marking "THIS SIDE UP" facing upfront.