  • Page 1 wienet Router v2 Expansion ports User guide Doc. no. BA000917 Last updated: 01/2019 (Rev. B)
  • Page 2 Wieland Electric GmbH is prohibited. wienet is a trademark of Wieland Electric. Other names may in this assembly manual men- tioned product and brand- trademarks or registered trademarks of their respective owners could be used, whose use by third parties for their own purposes could violate the rights of the owners.
  • Page 3: Table Of Contents

    Technical specifications ................25 Delivery identification .................. 25 RS232 ....................26 RS232 description ..................26 Expansion port connection ................26 Port status ....................27 Technical specifications ................27 Delivery identification .................. 28 Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 4 Installation ..................45 11.1 Installing a router in a metal housing ............45 Customer support ................47 Appendix .................... 48 13.1 List of figures ....................48 13.2 List of tables ....................49 Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 5: About This Document

    The installation instructions accompanying the product are downloadable in the electronic catalog of Wieland Electric. Be sure to always use the infor- mation provided in the current version of this installation manual. The version and revision level can be seen in the title page and the footer.
  • Page 6: Symbols And Notations

    Refer to notes for special features of a device. Instructions also tell you about a potentially harmful situation. If it is not avoided, the sys- tem or something in its environment can be damaged. Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 7: Safety Instructions

    • When using the router in the close proximity of personal medical devices, such as car- diac pacemakers or hearing aids, you must proceed with heightened caution. Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 8: Expansion Port Safety

    • Use only the original Wieland accessories. Thus you will prevent possible health risks and damage to the devices and ensure compliance with all relevant provisions. Unau- thorised adjustments or use of unapproved accessories may result in damage to the ex- pansion port and breach of applicable laws.
  • Page 9: Product Disposal Instructions

    At the end of its life this product MUST NOT be mixed with other commercial waste for disposal. Check with the terms and condi- tions of your supplier for disposal information. Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 10: Cnt

    Alarm is possible send after time after which upper limit must be overrun. In case that it isn't any change on input, it is possible to define time after which the value on input will zero. Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 11: Binary Output

    (viz. picture) is mounted on pins, electric current value is 20 mA. When jumper J4 is not mounted, electric value is 8 μA. If current value is 20 mA, CNT has higher consumption, also it has higher resistance to industrial noise. Figure 1: CNT board Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 12: Expansion Port Connection

    Typical connection of the router measuring circuits: Figure 3: Connection of the router measuring circuits N OT I CE The router does not support modifying any signals of the CNT port, for example logical functions. Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 13: Description Of Protocol Xc-Cnt Modbus Ascii Slave

    Lower 16 bits of log actual number 0x000A Alarms actual status 0x0100 Binary inputs status 0x0200 Binary outputs status 0x0300 Recalculate value of analogy input AN1 (with sign) 0x0400 Recalculate value of analogy input AN2 (with sign) Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 14 3 – level on input BIN4 • bit 6 – level on output BOUT1 0x0F06 Recalculate AN1 value (with sign) 0x0F07 Recalculate AN2 value (with sign) 0x0F08 Upper 16 bits CNT1 0x0F09 Lower 16 bits CNT1 Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 15 1. log – lower 16 bits of counter CNT2 value 0x1010 1. log – prompt frequency CNT2 0x1011 1. log – average frequency CNT2 0x1012 1. log – minimal frequency CNT2 0x1013 1. log – maximal frequency CNT2 Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 16 AN1 – multiplicative constant (with sign) 0xF302 AN1 – additive constant (with sign) 0xF303 AN1 – hysteresis value (with sign) 0xF304 AN1 – lower limit (with sign) 0xF305 AN1 – upper limit (with sign) Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 17 • 5 → 16 samples 0xF500 CNT1 – multiplicative constant 0xF501 CNT1 – upper limit 0xF502 CNT1 – time of limit overrun [sec] 0xF503 CNT1 – time for metering reset [sec] Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 18: Port Status

    0 … 20 mA, 100 Ohms 2x binary inputs Reed contact with J4 - 20mA without J4 8μA 1x output (open collector) 30 V / 100 mA Others Voltage resistance Permanent Sleeping mode Controlled Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 19: Delivery Identification

    Delivery identification Table 5: CNT delivery Trade name Type name Power supply identification XC-CNT XC-CNT Internal or external supply Figure 4: Example of expansion port CNT la- Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 20: Eth

    The expansion port ETH is created as expansion port which enables to use of the next hardware interface of Wieland modems for next signal processing. This interface is physi- cal connected on RJ45 connector on appropriate modem. The expansion port ETH is inter- nal supplies from appropriate modem.
  • Page 21: Port Status

    -30 … +85 °C Standards Emission EN 55022/B Immunity ETS 300 342 Safety EN 60950 Ethernet Max. bit rate 100 Mbps (IEEE 802.3) Max. total cable length 100 m (300Bd, 200nF/km) Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 22: Delivery Identification

    Delivery identification Table 9: ETH delivery Trade name Type name Power supply identification XC-ETH XC-ETH Internal supply Figure 7: Example of expansion port ETH la- Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 23: Mbusd

    The expansion port MBUSD is created as expansion port which enables to use of the next hardware interface of Wieland routers for next signal processing. The expansion port MBUS is equipment of a MASTER type. This interface is physically connected on RJ45 connector on appropriate router.
  • Page 24: Overload Detection

    Green LED Indicates receive data Yellow LED Indicates transmit data Both LED lights Indicates short circuit on the MBUS N OT I CE Status indication is supported from 3 revision of boards. Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 25: Technical Specifications

    Max. total cable length 1000 m (300Bd, 200nF/km) Delivery identification Table 13: MBUS deliv- Trade name Type name Power supply ery identification XC-MBUS XC-MBUS External supply Figure 11: Example of expansion port MBUSD label Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 26: Rs232

    The expansion port RS232 is created as expansion port which enables to use of the next hardware interface of Wieland routers for next signal processing. This interface is physi- cally connected to the RJ45 connector on the appropriate router. The expansion port RS232 is internal supplies from appropriate router.
  • Page 27: Port Status

    EN 60747 RS232 specifications Max. operating bus current 15 mA (EN 1434) Max. data rate 230400 bps Max. overvoltage ±30 V Max. total cable length 20 m (300 Bd, 200 nF/km) Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 28: Delivery Identification

    RS232 Delivery identification Table 17: RS232 deliv- Trade name Type name Power supply ery identification XC-RS232 XC-232 Internal supply Figure 16: Example of expansion port RS232 label Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 29: Rs485/Rs422

    The expansion port RS485/RS422 is created as an expansion board which enables the use of the next hardware interface of Wieland modems or routers for next signal processing. This interface is physically connected on RJ45 connector on appropriate modem or rout- ers.
  • Page 30: Expansion Port Connection Rs485

    N OT I CE The signals 3 – 5 and 4 – 6 are linked inside of the router. If galvanic separation is required, the converter must have an external power supply. Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 31: Expansion Port Connection Rs422

    Receive data (-) Output RxD+ Receive data (+) Output TxD- Transmit data (-) Input TxD- Transmit data (+) Input +12 V EXT External power supply +12 V EXT External power supply Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 32: Port Status

    Table 20: RS485/422 LED port indicator status indication Green LED Indicates receive data Yellow LED Indicates transmit data N OT I CE Status indication is supported from 4 revision of boards. Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 33: Technical Specifications

    1200 m (300Bd, 200nF/km) Delivery identification Table 22: 485/422 de- Trade name Type name Power supply livery identification XC-RS485/422 XC-485-422 Internal or external supply Figure 25: Example of expansion port RS485/422 label Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 34: Wifi Module

    WiFi module description The expansion port WiFi is created as an addition of router desk, allowing the use of wire- less interface in Wieland v2 routers. This expansion port is provided as an internal part of the router. WiFi module supports AP (Access Point) function. This module allows you to scan the neighboring networks.
  • Page 35: Module Configuration

    Table 24: Status infor- Item Desciption mation about WiFi cli- MAC address of associated station STA's unique AID (1 … 2007) or 0 if not yet assigned. Figure 27: WiFi AP sta- Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 36 Last response time of access point (AP). SSID Identifier for access point (AP). Supported rates Supported rates of access point (AP). DS Parameter set The channel on which broadcast access point (AP). Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 37 WiFi AP activity is indicated in rows starting “hostapd” or “dhcpd-wifi”. Press the Save button to save the system log to the computer. Figure 31: System Log Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 38: Wifi Configuration

    • WEP – Encryption using static WEP keys. This encryption can be used for Shared authentication. • TKIP – Dynamic encryption keys management, that can be used for WPA-PSK and WPA2-PSK authentication. • AES – Improved encryption used for WPA2-PSK authentication. Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 39 • Verbose debugging – The highest level of communicativeness. • Debugging • Informational – Default level of communicativeness that is used for writing standard events. • Notification • Warning – The lowest level of communicativeness. Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 40 WiFi Module Figure 32: WiFi AP configuration Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 41: Port Status

    Time in seconds that the client can use IP address. Figure 33: WLAN con- figuration Port status Table 29: WiFi status LED port indicator indication Green LED WiFi port power is on Yellow LED Permanent off Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 42: Technical Specifications

    50 Ohm Internal antenna impedance Frequency band 2.4 GHz Delivery identification Table 31: WiFi delivery Trade name Type name Power supply identification XC-WIFI XC-WIFI Internal supply Figure 34: Example of WiFi label Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 43: Sd Description

    In the opposite case (the item is not checked), SD port can be used as a USB flash drive (for connecting the router to the PC use A-A type of USB cabel). Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 44: Compatibility With Wieland Routers

    SD card extends the internal memory of the router. Yellow LED Indicates when a file is copied to the SD card 10.7 Delivery identification Table 34: SD delivery Trade name Type name identification Figure 38: Example of SD label Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 45: Installation

    B-RB-v2 (pos. 1) from the top. Connect the expansion port PORT2 (pos. 3) to the connector J3 (see figure above) on the router's motherboard B-RB-v2 (pos. 1) from the top. Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 46 Close the rear panel (pos. 6) by screwing the four screws (pos. 11) back in. Attach the label that is included in the delivery to the side of the router (see figure below). Figure 40: Router with label for expansion ports Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 47: Customer Support

    Advice on upkeep: When cleaning the router do not use aggressive chemicals, solvents or abrasive cleaners! Wieland Electric hereby declares that the routers described in this user’s guide fits all basic demands of directive 2014/53/EU (R&TTE). Router fits values of coefficient SAR defined by association ICNIRP and values of “About protection of health before non-ionized radiation“.
  • Page 48: Appendix

    Figure 37: Enable expansion port 2 ..................44 Figure 38: Example of SD label ................... 44 Figure 39: Router in metal housing ..................45 Figure 40: Router with label for expansion ports ..............46 Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 49: List Of Tables

    Table 30: WiFi technical specifications ................42 Table 31: WiFi delivery identification .................. 42 Table 32: SD Technical specifications ................. 44 Table 33: State identification ....................44 Table 34: SD delivery identification ..................44 Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)
  • Page 50 Wieland Electric GmbH Brennerstraße 10–14 D-96052 Bamberg Tel. 49 (0) 951 / 9324-0 Fax 49 (0) 951 / 9324-128 Email info@wieland-electric.com http://eshop.wieland-electric.com http://www.wieland-electric.com Wieland Electric GmbH | BA000917 | 01/2019 (Rev. B)

Table of Contents