LMS 16-W Ethernet switch USER MANUAL Doc.-No. BA001108 Updatet:01/2017 (Rev. A)
Page 2
COPYRIGHT This document is copyright-protected. The rights derived from this copyright are reserved for Wieland Electric GmbH. Reproduction of this document or parts of this document is only permissible within the limits of the statutory pro- vision of the Copyright Act. Any modification or abridgment of the document is prohibited without the express written agreement of Wieland Electric GmbH.
"Danger" or "Warning" are strictly used for cases which present a risk to life or limb. Damage to property only falls into these categories if there is also a risk of personal injury that corresponds to these levels. Wieland Electric GmbH | BA001108 (Rev. A) | 01/2017...
At the end of it’s life this product MUST NOT be mixed with other commercial waste for disposal. Check the terms and conditions of your supplier for disposal information. Wieland Electric GmbH | BA001108 (Rev. A) | 01/2017...
LMS 16-W is between -40 ~ 75 ℃. With such a wide range, you wienet The operating temperature of the can use the wienet LMS 16-W in some of the harshest industrial environments that exist. Wieland Electric GmbH | BA001108 (Rev. A) | 01/2017...
• 1 x wienet LMS 16-W Industrial Ethernet Switch • 1 x Wall mounting bracket and screws • 1 x DIN-rail mounting bracket and screws (preassembled) • 1 x Installation instructions Wieland Electric GmbH | BA001108 (Rev. A) | 01/2017...
LMS 16 Rear View Bottom View Top View Ordering code Ordering code is shown in the table below. Name Order code Features – interfaces LMS 16-W 83.040.1334.0 16x ETH 10/100 TX Wieland Electric GmbH | BA001108 (Rev. A) | 01/2017...
1. Switch off the power supply. 2. Lightly push the switch down and tilt the lower part of the switch away from the DIN-Rail. 3. Pull the switch upwards off the DIN-Rail. Wieland Electric GmbH | BA001108 (Rev. A) | 01/2017...
9. Insert the wall sinks into the walls. 10. Insert the screws into the wall sinks. Leave a 2 mm gap between the wall and the screw head to al- low for wall mounting plate insertion. Wieland Electric GmbH | BA001108 (Rev. A) | 01/2017...
Power input 2 is inactive P-Fail Power input 1 or 2 is in- active Power input 1 and 2 are active or no power input Loop Loop is detected No loop detected Wieland Electric GmbH | BA001108 (Rev. A) | 01/2017...
MDI port.The switch supports auto-crossover to make networking more easy and flexible. You can connect any RJ-45 (MDI-X) station port on the switch to any device such as a switch, bridge or switch. Wieland Electric GmbH | BA001108 (Rev. A) | 01/2017...
N OT E Note! Routing communications and power wiring through the same conduit may cause signal interference. To avoid interference and signal degradation, route power and communications wires through separate con- duits. Wieland Electric GmbH | BA001108 (Rev. A) | 01/2017...
Standards and regulations Telecom and emission ETSI EN 300 328 v1.8.1 U.S.A.: FCC Part 15 CISPR 22 IEC61000-4-2/3/4/5/6/8 EN61000-6-1/2/3/4 Safety EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013, EN 62311:2008 Wieland Electric GmbH | BA001108 (Rev. A) | 01/2017...
The transmission of data packets doesn’t work although the LED indicators are normal and the connected cables are correct. • Check your system's ethernet devices, their status and the network or device configuration. 8 Recommended Literature Wieland Electric: Installation instructions, Wieland Electric GmbH | BA001108 (Rev. A) | 01/2017...