Trane Sintesis RTAF HE series Installation Operation & Maintenance page 99

R134a, r513a, r1234ze air-cooled helical-rotary chillers 300 - 1900 kw
Table of Contents

Advertisement

Elastomeric Isolators Installation
(Optional)
Isolators are ready to install. Mountings have to
be placed on a rigid and level foundation. External
Sound power levels
equipment should not transmit additional vibration to
the chiller. The position of elastomeric isolator and
Discharge
weight per point are given in the Neoprene isolators
installation drawing which is supplied with the chiller.
Measurement conditions:
Wrong placement along the unit may result in excessive
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
deflection.
long) fixed to its discharge opening.
1.
Secure the isolators to the mounting surface
Fan
using the mounting slots in the isolator's base
Unit
speed
plate. Do NOT fully tighten the isolators mounting
1
bolts at this time. See the isolators submittals for
FWD 08
2
3
isolators location, maximum weights, and isolators
1
diagrams.
FWD 10
2
2.
Align the mounting holes in the base of the unit
3
with the threaded positioning pins on the top of the
1
FWD 12
2
isolators.
3
3.
Install the unit on the isolators and secure the
1
isolators to the unit with a nut. The maximum
FWD 14
2
3
isolators deflection should be 13 mm.
1
4.
Level the unit carefully. Fully tighten the isolator
FWD 20
2
mounting bolts.
3
Figure 1 – Elastomeric Isolator
Intake
117.6
Measurement conditions:
Measurements taken at the horizontal air intake.
Fan
159
Unit
speed
1
63.5
FWD 08
2
3
1
FWD 10
2
14.2
3
1
FWD 12
2
3
1
FWD 14
2
3
2
1
FWD 20
2
3
1
2
4
1
3
RLC-SVX19G-GB
UNT-PRC002-GB
Power level in dB(A), per Hz frequency band
125
250
55
50
57
54
58
57
57
51
58
54
60
58
57
51
58
54
60
58
56
62
61
66
63
69
57
63
61
66
63
69
9.6
40.6
Power level in dB(A), per Hz frequency band
127
125
250
56
55
63
62
66
65
62
58
66
63
70
16
70
67
62
58
66
63
70
67
66
65
73
72
78
76
4
6
68
72
76
76
78
79
3
5
6
5
Isolator Pads Installation (Optional)
Isolators are ready to install. Mountings have to
be placed on a rigid and level foundation. External
equipment should not transmit additional vibration to
the chiller. The position of pads isolator is given in the
pad isolators installation or selection drawing which is
supplied with the chiller.
Figure 2 – Isolator pads
500
1000
2000
42
37
37
47
40
30
50
42
32
45
42
34
48
45
38
50
48
40
45
42
34
48
45
38
2
50
48
40
50
48
39
RTAF 090_105_125_145_155_175
55
53
47
58
56
50
51
49
40
1
55
53
47
58
56
50
2
RTAF 190 HE_190 XE_190 HSE_205 HE_205 XE_205 HSE
1
500
1000
2000
55
53
46
60
60
53
12.7
63
62
56
55
58
51
60
62
56
63
65
59
55
58
51
60
62
56
63
65
59
65
65
57
69
71
64
73
75
69
64
64
56
68
71
65
71
74
69
8
7
Installation Requirements
90
4000
8000
31
30
38
40
450
40
43
33
28
8
39
35
42
39
33
28
39
35
4
6
42
39
38
36
46
45
50
49
39
37
3
5
46
45
50
49
4
6
3
5
4000
8000
45
42
53
53
55
57
48
44
55
52
59
57
48
44
55
52
59
57
50
46
59
57
64
63
52
50
61
61
66
66
Overall power
dB(A)
46
50
53
48
51
54
48
51
54
56
60
63
57
60
63
8
7
Overall power
dB(A)
57
64
67
61
66
69
61
66
69
68
74
78
69
75
78
11
99