Trane Sintesis RTAF HE series Installation Operation & Maintenance page 34

R134a, r513a, r1234ze air-cooled helical-rotary chillers 300 - 1900 kw
Table of Contents

Advertisement

General Data
Table 8a – General Data RTAF 090-245 Extra Efficiency - Extra Low Noise - R134a - R513A (continued)
Standard / High ambient fan option
FWD
Fan / motor Type
Power supply
Airflow per Fan
Capacities
Cooling capacity on water (1)
Max Power input per Motor
Heating capacity on water (2)
Max Amps per Motor
Fan motor
Motor RPM
Fan power input (3)
Low ambient fan option
Current amps (3)
Start-up amps
Fan / motor Type
Air flow
Airflow per Fan
minimum
Max Power input per Motor
nominal
Max Amps per Motor
maximum
Motor RPM
Main coil
Water entering/leaving connections
System data (5)
Nb of refrigerant circuit
Electric heater (accessory for blower only)
Minimum cooling load % (4) (7)
Electric power supply
R134a/R513A refrigerant charge
Heating capacity
Circuit 1 / Circuit 2 (8)
Hot water coil (accessory for blower only)
Oil charge Circuit 1 / Circuit 2
Heating capacity (4)
G2 filter (filter box accessory)
POE Oil type
Quantity
Dimensions ( LxWxth)
G4 filter (filter box accessory)
Quantity
Dimensions ( LxWxth)
Condensate pump (accessory)
(1) Indicative performance at Evaporator water temperature: 12°C / 7°C - Condenser air temperature 35°C - for detailed performances consult
Water flow - lift height
Order Write Up.
Not available for FWD30 and FWD45
(2) Under 400V/3/50Hz.
Sound level (L/M/H speed)
(3) Rated Condition without Pump Package.
Sound pressure level (5)
(4) Percent minimum load may be adjusted around 15%-20% according to operating conditions by local sales office.
Sound power level (5)
(5) Electrical & system data are indicative and subject to change without notice. Please refer to unit nameplate data.
Unit dimensions
(6) Not applicable for Glycol application - see tables with Minimum Flow with Glycol.
Width x Depth
(7) Max speed - range is 60% to 100% of max speed.
Height
(8) Refrigerant charge may vary according to option - for instance +20% for process (digit 19=P). For real value refer to unit nameplate.
Shipped unit dimensions
(9) Data containing information on two circuits shown as follows: ckt1/ckt2.
Width x Depth
Height
Weight
Colour
Recommended fuse size
Unit alone (aM/gI)
Unit with electric heater (gI)
(1) Conditions: Water entering/leaving temperature: 7/12 °C, Air inlet temperature 27/19°C DB/WB - Nominal air flow
(2) Conditions: Water entering/leaving temperature: 50/45 °C, Air inlet temperature 20°C DB - Nominal air flow
(3) At high speed with nominal air flow.
(4) Water entering/leaving temperature 90/70 °C, air inlet temperature 20 °C DB, Nominal air flow.
(5) A rectangular glass wool duct 1m50 long is placed on the blower.The measurement is taken in the room containing the blower unit.
Heat exchanger operating limits:
FWD:
*water temperature: max 100° C
*absolute service pressure: min 1 bar/max 11 bars
Accessories - Hot water coil:
*water temperature: min. +2° C/max. 100° C
*absolute service pressure: min 1 bar/max 11 bars
34
4
Technical Data
RTAF
RTAF
090
105
XE XLN
XE XLN
08
(V/Ph/Hz)
(m 3 /h)
15000
17400
(kW)
5,2
(kW)
0.5
0.8
(kW)
6,3
(A)
0.8
1.2
(type)
(rpm)
660
760
(kW)
0,23
(A)
1,1
(A)
3,2
(m3/h)
15000
17400
(m
/h)
490
3
(kW)
0.5
0.8
(m
/h)
820
3
(A)
0.8
1.2
(m
/h)
980
3
(rpm)
660
760
(type)
(Dia)
3/4"
#
2
2
%
30
30
(V/Ph/Hz)
230/1/50
(kW)
2/4
(kg)
43/41
42/40
(l)
6/6
6/6
(kW)
6,3
2
(mm)
386x221x8
-
(mm)
-
(type)
(l/h - mm)
(dB(A))
36/40/43
(dB(A))
46/50/53
(mm)
890 x 600
(mm)
250
(mm)
933 x 644
(mm)
260
(kg)
32
(A)
8/16
(A)
16 (2kW),25 (4kW)
RTAF
RTAF
RTAF
125
145
155
XE XLN
XE XLN
XE XLN
12
Propeller fan / Variable speed - EC motor
230/1/50
17400
17400
17400
8,3
0.8
0.8
0.8
11,9
1.2
1.2
1.2
2 x direct drive centrifugal
760
760
760
0,46
2,2
Propeller fan / Variable speed - EC motor
5,5
17400
17400
17400
980
0.8
0.8
0.8
1650
1.2
1.2
1.2
1970
760
760
760
ISO R7 rotating female
3/4"
2
2
2
30
30
30
230/1/50 or 400/3/50
400/3/50
8
45/41
48/46
50/44
6/6
6/6
7/6
12
OIL0048E or OIL0023E
2
486x271x8
586x321x8
2
486x264x48
586x314x48
Centrifugal
24 - 500
38/41/44
46/50/53
48/51/54
56/60/63
1090 x 710
1290 x 820
300
1133 x 754
1333 x 864
310
46
galvanised steel
8/16
40 (230V),3*16 (400V)
RTAF
RTAF
RTAF
175
190
205
XE XLN
XE XLN
XE XLN
20
30
20000
20000
20000
15
18,8
1.1
1.1
1.1
18,9
20,9
1.8
1.8
1.8
860
860
860
0,65
1,04
3,1
4,7
9,3
14,1
20000
20000
20000
1400
1800
1.1
1.1
1.1
2300
3000
1.8
1.8
1.8
2600
3600
860
860
860
1 1/2"
1 1/2"
1 1/2"
2
2
2
30
30
30
400/3/50
400/3/50
10
12
60/46
62/56
66/62
7/6
7/7
8/8
17,4
22,4
2
2
586*421*8
586*621*8
2
2
586*414*48
586*614*48
47/52/57
47/52/58
57/62/67
57/62/68
1290 x 970
1290 x 1090
350
450
1333 x 1008
1333*1133
360
460
61
76
8/16
8/25
3*20
3*25
UNT-PRC002-GB
RLC-SVX19G-GB
RTAF
245
XE XLN
45
20000
30,1
1.1
38,2
1.8
860
1,51
5,5
16,5
20000
2700
1.1
4500
1.8
5400
860
2
30
12
66/62
8/8
34,5
2
2
650
660
118
8/25
3*25

Hide quick links: