Figure 12 – Pump Curve - Sizes 250 - 450 - Standard Head - Standard Tubes
350
Sound power levels
1
Discharge
300
Measurement conditions:
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
long) fixed to its discharge opening.
250
Fan
Unit
speed
1
FWD 08
2
3
1
FWD 10
2
3
200
1
FWD 12
2
3
1
FWD 14
2
3
1
150
FWD 20
2
3
Intake
Measurement conditions:
100
Measurements taken at the horizontal air intake.
Fan
Unit
speed
1
FWD 08
2
50
3
1
FWD 10
2
3
1
FWD 12
2
3
0
1
0
5
10
15
FWD 14
2
3
1
FWD 20
2
3
Note: Standard Head pump not available in sizes 370, 400, 510 and 550.
RLC-SVX19G-GB
UNT-PRC002-GB
Power level in dB(A), per Hz frequency band
125
250
55
50
57
54
58
57
57
51
58
54
60
58
57
51
58
54
60
58
56
62
61
66
63
69
57
63
61
66
63
69
12
9
Power level in dB(A), per Hz frequency band
7
125
250
8
56
55
63
62
66
65
62
58
66
63
70
67
62
58
66
63
70
67
66
65
20
25
30
35
40
45
50
73
72
Water flow rates (l/s)
78
76
68
72
76
76
78
79
Optional Integrated Pump Package
500
1000
42
37
47
40
50
42
45
42
48
45
50
48
45
42
48
45
50
48
50
48
55
53
58
56
51
49
55
53
58
56
11
500
1000
55
53
60
60
63
62
55
58
60
62
63
65
55
58
13
60
62
2
3
63
65
65
65
55
60
65
70
75
80
69
71
73
75
64
64
68
71
71
74
1. RTAF 250 SE-HSS-HE-XE-HSE
2. RTAF 280 SE-HSS-HE-XE-HSE
3. RTAF 310 SE-HSS-HE-XE-HSE
2000
4000
8000
4. RTAF 350 SE-HSS-HE-XE-HSE
37
31
30
30
38
40
32
40
43
5. RTAF 380 SE-HSS-HE-XE-HSE
34
33
28
38
39
35
40
42
39
6. RTAF 410 SE-HSS-HE-XE-HSE
34
33
28
/
38
39
35
RTAF 450 HSE
40
42
39
7. RTAF-G 210
39
38
36
47
46
45
50
50
49
8. RTAF-G 230
40
39
37
47
46
45
50
50
49
9. RTAF-G 265
11. RTAF-G 285 / 191
2000
4000
8000
46
45
42
53
53
53
56
55
57
51
48
44
56
55
52
59
59
57
51
48
44
56
55
52
6
4
5
59
59
57
57
50
46
85
90
95
100
64
59
57
69
64
63
56
52
50
65
61
61
69
66
66
Overall power
dB(A)
46
50
53
48
51
54
48
51
54
56
60
63
57
60
63
Overall power
dB(A)
57
64
67
61
66
69
61
66
69
68
74
78
69
75
78
11
111

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sintesis rtaf 090 se sn lnSintesis rtaf se seriesSintesis rtaf 105 se sn lnSintesis rtaf 125 se sn lnSintesis rtaf xe seriesSintesis rtaf 140 se sn ln ... Show all