Table 2a – General Data RTAF 090-245 Standard Efficiency - Standard and Low Noise (SN&LN) - R134a - R513A
Cooling Capacity (1)
Sound power levels
Unit electrical data (2) (3) (5)
Maximum Power input in
cooling
Discharge
Unit rated amps (Max compr
+Fan+Control)
Measurement conditions:
Unit start up amps
(Starting Amps of the
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
largest compr+RLA of 2nd
compr+RLA of all fans+
long) fixed to its discharge opening.
control)
Displacement Power Factor
(DPF)
Unit
speed
Max power cable cross
(mm 2 )
section
FWD 08
Disconnect switch size
Compressor
Quantity
FWD 10
Type
Model (9)
FWD 12
Max Compr Power input
Circuit 1/Circuit 2
Max Amps Circuit 1 / Circuit
2 (3) (5)
FWD 14
Start up Amps Circuit 1 /
Circuit 2 (3) (5)
Motor RPM
FWD 20
Oil sump heater Circuit 1 /
Circuit 2
Evaporator
Intake
Quantity
Type
Measurement conditions:
Evaporator model
Measurements taken at the horizontal air intake.
Evaporator Water Content
volume
Antifreeze Heater
Unit
speed
Two pass evaporator
Evap. Water Flow rate -
FWD 08
Minimum
Evap. Water Flow rate -
Maximum (6)
FWD 10
Nominal water connection
size (Grooved coupling)
Two pass evaporator with turbulator
FWD 12
Evap. Water Flow rate -
Minimum (6)
Evap. Water Flow rate -
FWD 14
Maximum
Nominal water connection
size (Grooved coupling)
FWD 20
Hydraulic Module Components
Standard head pressure pump option (Twin pump)
Available Head Pressure
(1)
Max Motor Power input
Max Amps
High head pressure pump option (Twin Pump)
Available Head Pressure
(1)
Max Motor Power input
Max Amps
Expansion Tank Volume
Max User water loop
Volume for factory mounted
expansion tank (1)
Max. Water-side Operating
Pressure without pump
package
Max. Water-side Operating
Pressure with pump
package
Antifreeze Heater with
pump package
RLC-SVX19G-GB
UNT-PRC002-GB
RTAF
RTAF
RTAF
090
105
125
SE SN LN SE SN LN SE SN LN SE SN LN SE SN LN SE SN LN SE SN LN SE SN LN SE SN LN SE SN LN SE SN LN SE SN LN SE SN LN SE SN LN
(kW)
326
375
440
(kW)
136.4
157.6
185.8
(A)
229
267
317
(A)
276
331
442
0.87
0.86
0.85
Fan
Power level in dB(A), per Hz frequency band
125
250
1x240
1x240
1x240
1
55
50
2
57
54
(A)
400
400
500
3
58
57
1
57
51
#
2
2
2
2
58
54
Screw
Screw
Screw
3
60
58
45/45
50/50
70/50
1
57
51
2
58
54
kW
60/60
71/71
99/71
3
60
58
1
56
62
(A)
97/97
116/116 166/116 166/166 166/166 201/166 201/166 201/201 240/166 240/201 240/201 240/240 240/240 240/240
2
61
66
3
63
69
(A)
144/144 180/180 291/180 291/291 291/291 354/291 354/291 354/354 354/291 354/354 354/354 354/354 354/354 354/354
1
57
63
(rpm)
3000
3000
3000
2
61
66
3
63
69
(W)
150/150 150/150 150/150 150/150 150/150 150/150 150/150 150/151 150/150 150/150 150/150 150/150 150/150 150/150
#
1
1
1
115B
115A
165B
(l)
51
58
74
(W)
1640
1640
1640
Fan
Power level in dB(A), per Hz frequency band
125
250
1
56
55
(l/s)
8.0
9.4
11.6
2
63
62
3
66
65
(l/s)
29.6
34.7
43.1
1
62
58
2
66
63
(in) -
4" - 100 4" - 100 5" - 125 5" - 125 5" - 125 5" - 125 5" - 125 5" - 125 5" - 125 6" - 150 6" - 150 6" - 150 6" - 150 6" - 150
(DN)
3
70
67
1
62
58
2
66
63
(l/s)
6.6
7.8
9.7
3
70
67
1
66
65
(l/s)
26.6
31.2
38.7
2
73
72
3
78
76
(in) -
4" - 100 4" - 100 5" - 125 5" - 125 5" - 125 5" - 125 5" - 125 5" - 125 5" - 125 6" - 150 6" - 150 6" - 150 6" - 150 6" - 150
(mm)
1
68
72
2
76
76
3
78
79
(kPa)
140
128
142
(kW)
5.5
5.5
7.5
(A)
11
11
14
(kPa)
252
239
223
(kW)
11.0
11.0
11.0
(A)
21
21
21
(l)
80
80
80
(l)
6000
6000
6000
(kPa)
1000
1000
1000
(kPa)
450
450
450
(W)
2400
2400
2400
RTAF
RTAF
RTAF
RTAF
140
145
150
155
505
522
542
564
214
217.7
236.4
240.1
367
375
402
410
492
500
555
563
0.85
0.84
0.85
0.85
500
1000
2x300
2x300
2x300
2x300
42
37
47
40
630
630
630
630
50
42
45
42
2
2
2
2
48
45
Screw
Screw
Screw
Screw
50
48
70/70
70/70
85/70
85/70
45
42
48
45
99/99
99/99
121/99
121/99
50
48
50
48
55
53
58
56
51
49
3000
3000
3000
3000
55
53
58
56
1
1
1
1
Flooded shell and tube heat exchanger
165B
165B
165A
165A
74
74
78
78
1640
1640
1640
1640
500
1000
55
53
11.6
11.6
12.4
12.4
60
60
63
62
43.1
43.1
46.0
46.0
55
58
60
62
63
65
55
58
60
62
9.7
9.7
10.3
10.3
63
65
65
65
38.7
38.7
41.3
41.3
69
71
73
75
64
64
68
71
71
74
119
119
177
177
7.5
7.5
11.0
11.0
14
14
21
21
NA
244
NA
235
NA
15.0
NA
15.0
NA
28
NA
28
NA
80
NA
80
NA
6000
NA
6000
NA
1000
NA
1000
NA
450
NA
450
2400
2400
2400
2400
General Data
RTAF
RTAF
RTAF
RTAF
170
175
185
190
581
615
655
675
258.8
263.0
285.4
289.1
437
449
484
492
590
574
637
645
0.86
0.85
0.86
0.85
2000
4000
2x300
2x300
2x300
2x300
37
31
30
38
630
630
800
800
32
40
34
33
2
2
2
2
38
39
Screw
Screw
Screw
Screw
40
42
85/85
100/70
100/85
100/85
34
33
38
39
121/121
144/99
144/121 144/121 144/144 144/144 144/144
40
42
39
38
47
46
50
50
40
39
3000
3000
3000
3000
47
46
50
50
1
1
1
1
200B
200B
200B
200B
99
99
99
99
2040
2040
2040
2040
2000
4000
46
45
12.4
12.4
14.2
14.2
53
53
56
55
46.0
46.0
52.6
52.6
51
48
56
55
59
59
51
48
56
55
10.3
10.3
11.8
11.8
59
59
57
50
41.3
41.3
47.2
47.2
64
59
69
64
56
52
65
61
69
66
NA
173
154
154
NA
11.0
11.0
11.0
NA
21
21
21
NA
231
264
264
NA
15.0
18.5
18.5
NA
28
35
35
NA
80
80
80
NA
6000
6000
6000
NA
1000
1000
1000
NA
450
450
450
2800
2800
2800
2800
RTAF
RTAF
RTAF
200
205
245 (10)
707
732
816
308.3
312.0
312
523
531
530
637
645
644
0.85
0.85
0.85
Overall power
8000
dB(A)
2x300
2x300
2x300
30
46
40
50
800
800
800
43
53
28
48
2
2
2
35
51
Screw
Screw
Screw
39
54
100/100 100/100 100/100
28
48
35
51
39
54
36
56
45
60
49
63
37
57
3000
3000
3000
45
60
49
63
1
1
1
250C
250C
250B
109
109
118
2040
2040
2040
Overall power
8000
dB(A)
42
57
16.2
16.2
17.9
53
64
57
67
60.3
60.3
66.5
44
61
52
66
57
69
44
61
52
66
13.5
13.5
14.9
57
69
46
68
54.1
54.1
59.7
57
74
63
78
50
69
61
75
66
78
143
143
143
11.0
11.0
11.0
21
21
21
254
254
254
18.5
18.5
18.5
35
35
35
80
80
80
6000
6000
6000
1000
1000
1000
450
450
450
2800
2800
2800
9 1 1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: