Important Safety Information; Grounding Instructions; Warning C0 2 Can Be Dangerous - Danby Silhouette DKC646BLS Owner's Manual

Keg cooler
Table of Contents

Advertisement

IMPORTANT SAFETY INFORMATION

READ ALL SAFETY INFORMATION BEFORE USING
GROUNDING
INSTRUCTIONS
FOR YOUR
SAFETY...
Pertaining to the risk
of Fire, Electric Shock
or Injury to Persons.
WARNING CO
CAN BE
DANGEROUS!
CO
Cylinders when
2
charged contain high
pressure compressed gas
which can be hazardous if
not handled properly. Read
and understand the
following procedures for
CO
cylinders before
2
installation;
WARNING
If it becomes difficult to
breathe and/or your head
starts to ache, abnormal con-
centrations of carbon dioxide
(CO
) may be present in the
2
area....
CLOSE THE MAIN VALVE ON
THE CO 2 CYLINDER,
VENTILATE AND LEAVE THE
ROOM IMMEDIATELY!
• This appliance must be grounded. In the event of a
malfunction or breakdown, grounding will reduce the risk
of electric shock by providing a path of least resistance
for electric current.
• This appliance is equipped with a power cord having an
equipment grounding conductor and grounding plug. The
plug must be plugged into an appropriate wall outlet that
is installed and grounded in accordance with all existing
local codes and ordinances.
• Consult a qualified electrician or serviceman if the
grounding instructions are not clearly understood, or if
doubt exist as to whether your electrical wall outlets are
properly grounded.
2
1. Always connect a CO 2
gas cylinder to a regula-
tor. Failure to do so could
result in an explosion
which can possibly result
in death or injury when the
cylinder valve is opened.
2. Never connect a C0 2 gas
cylinder directly to beer
keg.
3. Always secure a C0 2 gas
cylinder in an "upright"
position.
4. Always keep a CO 2 gas
cylinder away from heat.
5. Never drop or throw a
CO 2 gas cylinder.
6. Always check the D.O.T.
(Department of Transport)
test date located on the
neck of the cylinder before
installation. If over five (5)
years, do not use, return
the gas cylinder to gas
supplier.
4
7. Never connect a product
container unless there
are two (2) safety
mechanism's in the
pressure system;
(a) One at or on the CO 2
regulator.
(b) One at or on the
product container coupler
in the pressure gas line.
NOTE: The regulator and keg
coupler supplied with this unit
are inclusive of such safety
mechanisms.
8. CO 2 gas cylinders should
be stored in the coolest
part of the establishment
(preferably) at 70ºF (21ºC)
and must always be
securely fastened in an
"upright" position.
9. Always ventilate area after
any leakage of CO 2 .

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents