Analog Input Configuration; Digital I/O Configuration; Counter Configuration - National Instruments Corporation DAQCard-500 User Manual

Multifunction i/o card for type ii pcmcia bus
Table of Contents

Advertisement

Chapter 2
If you are using LabWindows/CVI, the software installation instructions are in Part 1,
Introduction to LabWindows/CVI, of the Getting Started with LabWindows/CVI manual. After
you have installed LabWindows/CVI, refer to Chapter 1, Configuring LabWindows/CVI, of the
LabWindows/CVI User Manual for software configuration instructions.
If you are a register-level programmer, refer to the DAQCard-500 Register-Level Programmer
Manual.

Analog Input Configuration

The DAQCard-500 is always configured as follows:
Single-ended input mode referenced to analog ground
±5 V analog input range

Digital I/O Configuration

The DAQCard-500 always uses one 4-bit digital output port and one 4-bit digital input port.

Counter Configuration

You can use the MSM82C54 counter/timers for general-purpose applications, such as pulse and
square wave generation, event counting, and pulsewidth, time-lapse, and frequency
measurement. For information about configuring the MSM82C54, see the Timing Connections
section of Chapter 3, Signal Connections.
© National Instruments Corporation
2-3
Installation and Configuration
DAQCard-500 User Manual

Advertisement

Table of Contents
loading

Table of Contents