Do you have a question about the 7S21FNI SL and is the answer not in the manual?
Questions and answers
MOHAMAD YUSSOF BIN KASSIM
March 1, 2025
Top up gas 7yrs already..ice cube not solid
1 comments:
Mr. Anderson
March 1, 2025
To fix the issue of ice cubes not solidifying in the Whirlpool refrigerator model 7S21FNI SL after 7 years of use, follow these steps:
1. Check Freezer Temperature – Ensure the freezer is set to the correct temperature (typically around -18°C or 0°F). 2. Inspect Freezer Door Seal – Make sure the door seal is intact and closing properly to prevent warm air from entering. 3. Verify Airflow – Ensure that vents inside the freezer are not blocked by food items, allowing proper cold air circulation. 4. Check for Frost Buildup – If there is excessive frost, the defrost system may not be working properly. Inspect the defrost sensor (E9 fault code may indicate failure). 5. Inspect Evaporator Fan – If the fan is not running, cold air may not be circulating properly. Replace if faulty. 6. Ensure Compressor is Functioning – If the compressor is frequently tripping, check for refrigerant leaks or an issue with the overload protection device. 7. Power Supply Check – Ensure the refrigerator is receiving stable voltage as fluctuations can affect cooling performance. 8. Clean Condenser Coils – Dust buildup can reduce cooling efficiency; clean the coils regularly. 9. Check Ice Maker Operation – If using an automatic ice maker, ensure the water supply is functioning properly.
If the issue persists, consider consulting a professional technician for further diagnosis.
Page 1
7S21FNISL/7S21FNNSL Service Manual Table of Contents Appearance and Parts Diagram Technical Specifications Control System Control Panel and Operation Fault Handling...
Page 2
Section I: Appearance Section II: Technical Specifications Model Number 7S21FNISL/7S21FNNSL Rated Power Input (W) Climate Type 3, SN/N/ST/T Defrost Wattage (W) Protection against Power Consumption (Kwh/24h) 1.19 electric shock Frozen stars Noise Sound Level (dB) (A) Total Volume (L) Foaming Agent Cyclopentane Refrigerator Volume (L) Energy efficiency level...
Page 3
Section III: Control System Schematic Diagram 1. The Compressor: Compressor downtime must be greater than 5 minutes to open again. It is parked at an open cycle, once the freezer reaches the required temperature, only then will the compressor stop again. 2.
Page 4
6. Freezer & Ref LED Lamps and UV Light: When doors are open, all lights are turned on. When doors are closed, LED lamps are turned off immediately. The UV light will run for one more hour before it turns off. Section IV: Control Panel and Usage Control Panel and Use of each button To select an Operating Mode:...
Page 5
Quick Freeze Icon: Under the “Quick Freeze” mode, press and hold the “Freezer Temperature Adjustment” button for 3 seconds to adjust the “Quick Freeze” mode duration; it can range between 6-24 hours. Lock/Unlock Button: If buttons have not been pressed for 30 seconds, it will go into lock state automatically. Under the unlocked state, press the Lock / Unlock button for 3 seconds;...
Page 6
contacts/connectors. not cooling Make sure that the unit is plugged in to the power outlet; check if the evaporator fan. Make sure that the air damper is able to close and open properly. Temperature requirements for Check for refrigerant leaks both freezer and refrigerator Check for gasket leaks on both freezer compartment are not being...
Need help?
Do you have a question about the 7S21FNI SL and is the answer not in the manual?
Questions and answers
Top up gas 7yrs already..ice cube not solid
To fix the issue of ice cubes not solidifying in the Whirlpool refrigerator model 7S21FNI SL after 7 years of use, follow these steps:
1. Check Freezer Temperature – Ensure the freezer is set to the correct temperature (typically around -18°C or 0°F).
2. Inspect Freezer Door Seal – Make sure the door seal is intact and closing properly to prevent warm air from entering.
3. Verify Airflow – Ensure that vents inside the freezer are not blocked by food items, allowing proper cold air circulation.
4. Check for Frost Buildup – If there is excessive frost, the defrost system may not be working properly. Inspect the defrost sensor (E9 fault code may indicate failure).
5. Inspect Evaporator Fan – If the fan is not running, cold air may not be circulating properly. Replace if faulty.
6. Ensure Compressor is Functioning – If the compressor is frequently tripping, check for refrigerant leaks or an issue with the overload protection device.
7. Power Supply Check – Ensure the refrigerator is receiving stable voltage as fluctuations can affect cooling performance.
8. Clean Condenser Coils – Dust buildup can reduce cooling efficiency; clean the coils regularly.
9. Check Ice Maker Operation – If using an automatic ice maker, ensure the water supply is functioning properly.
If the issue persists, consider consulting a professional technician for further diagnosis.
This answer is automatically generated