Summary of Contents for Stoelting O111-I2F

  • Page 1 Model O111-I2F OPERATORS MANUAL Manual No. 513686 Rev.1...
  • Page 3 DO NOT ATTEMPT to operate the machine until instructions and safety precautions in this manual are read completely and are thoroughly understood. If problems develop or questions arise in connection with installation, operation, or servicing of the machine, contact Stoelting. Stoelting Foodservice Equipment Customer Service: 888.429.5920...
  • Page 4: Safety Information

    CAUTION If you need to replace a part, use genuine Stoelting The signal word “CAUTION” indicates a potentially parts with the correct part number or an equivalent hazardous situation, which, if not avoided, may result part.
  • Page 5: Table Of Contents

    TABLE OF CONTENTS Section Description Page Introduction Description ....................1 Specifications ..................... 1 Installation Instructions Safety Precautions ..................3 Shipment and Transit .................. 3 Machine Installation ..................3 IntelliTec2™ Setup ..................4 Initial Set-Up and Operation Operator’s Safety Precautions ..............7 Operating Controls and Indicators ..............
  • Page 7: Introduction

    SECTION 1 INTRODUCTION 1.1 DESCRIPTION The Stoelting O111-I2F counter-top machines are gravity fed. The machines are equipped with the IntelliTec2™ control which provides a uniform product. The machines are designed to operate with almost any type of com- mercial soft serve or non-dairy mixes available, including: ice milk, ice cream, yogurt, and frozen dietary desserts.
  • Page 8 Water cooled units require 1/2” N.P.T. water and drain fittings. Plumbing Fittings Maximum water pressure of 130 psi. Minimum water flow rate of 3 GPM. Ideal EWT of 50°-70°F Hopper Volume 6.5 gallons (24,61 liters) Freezing Cylinder 1 gallon (3,79 liters) Volume Operators Manual #513686 O111-I2F Model Machines...
  • Page 9: Installation Instructions

    Open the rear panel and check the belt tension customer must place claim for damages and/or shortages with a Burroughs Belt Tension Gauge. The tension in shipment with the carrier. Stoelting, Inc. cannot make should be 50-55 lbs. Adjust as necessary and any claims against the carrier.
  • Page 10: Intellitec2™ Setup

    Plug your USB flash drive into the control if it is not already plugged in. From the Current Status screen, press the left arrow button to access the passcode selection screen. Press the right arrow, SET, and then the SEL button. Operators Manual #513686 O111-I2F Model Machines...
  • Page 11 Consist Offset. 2. If the product is too firm, decrease the CutIn Consist Offset. After the consistency is set, press the left arrow button once so that the Modify Operating Settings screen is displayed. Operators Manual #513686 O111-I2F Model Machines...
  • Page 12 Operators Manual #513686 O111-I2F Model Machines...
  • Page 13: Initial Set-Up And Operation

    If the Main Power On/Off button is pressed when the machine is on, the machine turns off IntelliTec2™ Control (See Figure 3-2) Dispense Rate Adjustor Access Port Figure 3-1 Machine Controls Operators Manual #513686 O111-I2F Model Machines...
  • Page 14: Dispense Rate Adjustor

    Make sure the Main Freezer Power is on. If the Figure 3-3 Auger Flight Wear IntelliTec2™ displays the Current Status Screen, then the main power is on. Turn off the freezing cylinder by pressing the On/ Off button Operators Manual #513686 O111-I2F Model Machines...
  • Page 15: Disassembly Of Front Door

    Wrap the brush in a clean sanitized cloth and thoroughly dry the freezing cylinder. Remove the drip tray from the front panel. Clean and replace the drip tray. Operators Manual #513686 O111-I2F Model Machines...
  • Page 16: Assembling Machine

    Install the bushing onto the auger support and install the auger support into the front of the auger. Rotate the auger support so that one leg of the support points straight up. Operators Manual #513686 O111-I2F Model Machines...
  • Page 17: Freeze Down And Operation

    Press the CLEAN button to stop the auger. Allow technical problem may be related to the mix. the freezing cylinder to drain completely. The machine is now sanitized and ready for adding mix. Operators Manual #513686 O111-I2F Model Machines...
  • Page 18 Old mix, or mix that has been stored at too high a tempera- ture, can result in a finished product that is unsatisfactory. To retard bacteria growth in dairy based mixes, the best storage temperature range is between 33° to 38°F (0.5° to 3.3° C). Operators Manual #513686 O111-I2F Model Machines...
  • Page 19: Maintenance And Adjustments

    Remove the back panel. The condenser requires periodic cleaning. To clean, refer to the following procedures. Disconnect power to the machine Remove the Phillips head screws from the right side panel, and remove the panel. Operators Manual #513686 O111-I2F Model Machines...
  • Page 20: Preventative Maintenance

    Place the auger flights and auger support bushing in a plastic bag with a moist paper towel. This prevents them from becoming brittle if exposed to dry air over an extended period of time (over 30 days). Operators Manual #513686 O111-I2F Model Machines...
  • Page 21: Troubleshooting

    * After this error occurs, the machine goes into Sleep 3 If the error persists after attempting to clear it, mode where the compressor runs on timers and the drive contact your Authorized Stoelting Distributor for motor does not run. The timers keep the product at a safe further assistance.
  • Page 22 If the control panel displays an E5, On/Off button to turn if off then back on. If the press the On/Off button to turn if off then back error persists, contact your Authorized Stoelting on. If the error persists, contact your Authorized Distributor for further assistance.
  • Page 23: Troubleshooting - Machine

    3 Chipped or worn spigot o-rings. 3 Replace o-rings. Front door leaks. 4 O-rings or spigot installed wrong. 4 Remove spigot and check o-ring. 5 Inner spigot hole in front door nicked 5 Replace front door. or scratched. Operators Manual #513686 O111-I2F Model Machines...
  • Page 24 Operators Manual #513686 O111-I2F Model Machines...
  • Page 25: Replacement Parts

    Decal - Adequate Ventilation 3” 324594 Decal - Attention Heat Sensitive 324728 Decal - Contactor Identification 324803 Decal - Domed Stoelting Logo (Large) (Header Panel) 324888 Decal - Fan Motor Reset 324901 Decal - Transformer Switch 324909 Decal - USB Port...
  • Page 26: Front Door And Auger Parts

    O-Ring - Rear Seal - Black (5 Pack) 625133 O-Ring - Front Door - Red 666786 Seal - Rear Auger - Black 694255 Spring - Auger Flight 2177698 Door w/Pins 2187812 Spigot Body 3170644 Support - Front Auger 3156795 Auger Shaft Operators Manual #513686 O111-I2F Model Machines...
  • Page 27: Hopper Parts & Trays

    O-Ring - Mix Inlet Assembly - Black (5 Pack) 744283 Tray - Drip 744284 Insert - Drip Tray 744608 Tray - Drain (Black Plastic) 2203116 Mix Inlet Assembly - 5/16” Hole - 5/16” Air Operators Manual #513686 O111-I2F Model Machines...
  • Page 28 Operators Manual #513686 O111-I2F Model Machines...
  • Page 29 Stoelting’s sole obligations, and Buyer’s sole remedies, for any breach of this warranty shall be, at Stoelting’s option, one of the following: repair or replacement of the affected component at Stoelting’s plant in Kiel, Wisconsin, or refund of the purchase price of the affected Equipment. Stoelting, through an Authorized Stoelting Provider, will deinstall/reinstall the affected component from/into the equipment (“Labor”) for the period listed below in the Warranty...
  • Page 30 Costs not covered by the Stoelting Travel Pay policy. Stoelting covers only the first trip travel which is a flat rate by mileage one- way from the service company’s home location to the job site. The flat rate is calculated as follows:...