Download Print this page

Barksdale CSK Installation Instructions Manual page 2

Advertisement

OPERATING CHARACTERISTICS
PRESSURE
PRESSURE RANGE
MODEL
2
20 - 120 (1.4 - 8.3)
3
90 - 250 (6.2 - 17.2)
4
250 - 950 (17.2 - 65.5)
5
700 - 1900 (48.3 - 131)
6
1000 - 3000 (69 - 207)
SET POINT ADJUSTMENT:
The switch is factory set at approximately 50% of the maximum pressure range.
In order to change the setting of the switch follow the instructions below.
Caution: The adjustment screw is electrically conductive to the contacts. Therefore, to prevent an electric shock,
always use insulated tools and only monitor the circuit with a digital multimeter or low voltage (<12 VDC) LED light
while adjusting the setpoints. Never contact any conductive object, wire, cable, connector pin, or terminal blade
with a conductive portion of the adjusting tool while adjusting the switch.
Step 1: Insert a 1/8" allen key through the opening on the top center of the switch.
Step 2: Turn the allen key clockwise to increase the pressure setting and counter-
clockwise to decrease.
Note: If your product contains flying leads, you will have to remove the two pan Phillip head screw on the top of
the switch and remove the cap in order to access the
adjustment screw.
Caution: Failure to replace the adjustment screw cap will expose the user to the electrically live
adjustment screw
PROOF PRESSURE
PSI (BAR)
PSI (BAR)
9000 (600)
9000 (600)
9000 (600)
9000 (600)
9000 (600)
ELECTRICAL RATINGS
ELECTRICAL
RATINGS
8A @ 12VDC
1
4A @ 24VDC
2A @ 42VDC
33mA @ 12VDC
16mA @ 24VDC
2
13mA @ 30VDC
GOLD CONTACT
Rev 6

Advertisement