Summary of Contents for Panduit SynapSense 1167

  • Page 1 ® SynapSense 2.4GHz Industrial Gateway Model 1167 Installation & Use Manual...
  • Page 2 ® SynapSense 2.4GHz Industrial Gateway Hardware Installation Manual Release 0v6 Issue 1...
  • Page 3 This documentation might include technical inaccuracies or other errors. Corrections and improvements might be incorporated in new versions of the documentation. Panduit does not assume any liability arising out of the application or use of any products or services and specifically disclaims any and all liability, including without limitation consequential or incidental damages.
  • Page 4 (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the Panduit could void the user's authority to operate the equipment. The external antenna(s) used for this transmitter must not be co-located or operated in conjunction with any other antenna or transmitter.
  • Page 5 Neither is any liability assumed for damages resulting from the use of the information contained herein. Copyright © 2016 Panduit Corp. All rights reserved. No part of this book shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical, photocopying, recording or otherwise, without written permission from Panduit.
  • Page 6 ® SynapSense 2.4GHz Industrial Gateway Hardware Installation Manual...
  • Page 7: Table Of Contents

    Overview ............................8 About This Installation Guide ........................8 Organization ..............................8 Document Conventions ..........................9 Document References ..........................9 Warnings and Precautions ..........................9 Panduit Technical Support .......................... 11 Introduction ..........................12 Scope ................................12 Overview ............................... 12 ® SynapSense 2.4GHz Industrial Gateway Kit ....................
  • Page 8: Ghz Industrial Gateway

    Hardware Installation Manual Overview About This Installation Guide The intended audience for this document consists of customers or partners of Panduit. Customers, partners, or installers should receive training from Panduit prior to installing the hardware detailed in this document. Organization ®...
  • Page 9: Document Conventions

    ® SynapSense 2.4GHz Industrial 2.4GHz Industrial Gateway Installation Manual Document Conventions Table2 defines the style conven entions used throughout this document. Table 2 – Installation Guide St tyle Conventions Item Desc escription his style is used for anything a user types, cli cks, presses, Bold and Blue or t...
  • Page 10 ® SynapSense 2.4GHz Industrial 2.4GHz Industrial Gateway Hardware Installation Manua Avertissements et Precautions Avertissements et Precautions Les avertissements et précautions suivants concernent les installations de passerelle. Le Les avertissements et précautions suivants concernent les installations de passerelle. Le Les avertissements et précautions suivants concernent les installations de passerelle. Le non-respect des avertissements et des précautions peut entraîner des blessures respect des avertissements et des précautions peut entraîner des blessures respect des avertissements et des précautions peut entraîner des blessures...
  • Page 11: Panduit Technical Support

    ® SynapSense 2.4GHz Industrial Gateway Installation Manual Panduit Technical Support Severity 1 & 2 Issues: Americas: 1-866-721-5302 x86810 during normal Central Standard Time business hours EMEA: 44-1291-674-661 x22761 during normal U.K. business hours APAC: 65-8200-3931 or 65-8200-3932 between 8 a.m. and 5 p.m.
  • Page 12: Introduction

    ® SynapSense 2.4GHz Industrial Gateway Hardware Installation Manual Introduction This chapter provides the scope, overview and kit components for installing and ® configuring a SyapSense 2.4GHz Industrial Gateway. Scope This document provides guidelines and instructions for installing and configuring the Industrial Gateway.
  • Page 13: Synapsense 2.4Ghz Industrial Gateway Kit

    ® SynapSense 2.4GHz Industrial Gateway Installation Manual SynapSense ® 2.4GHz Industrial Gateway Kit The Industrial Gateway Kit contains the following components: ® 1 ea. SynapSense 2.4GHz Industrial Gateway (Part Number 100-1167-001)
  • Page 14 ® SynapSense 2.4GHz Industrial Gateway Hardware Installation Manual 1 ea. 2.4GHz Dipole Antenna, IP-67Rated. (LSR, Part Number 001-0010) 1 ea. M12-4/5, Plug, Cable, 3meter, A Coded, To Connect 10-30Vdc Power to Gateway...
  • Page 15 ® SynapSense 2.4GHz Industrial Gateway Installation Manual The following components are available as additional options for the Industrial Gateway: Industrial Gateway Mounting Plate (optional accessory) Allows Mounting of the Industrial Gateway to DIN rail using Std. Clip Industrial Gateway T-Mount Feet (optional accessory)
  • Page 16: Requirements

    ® SynapSense 2.4GHz Industrial Gateway Hardware Installation Manual Requirements This chapter lists the hardware, software, tools, and additional material requirements for installing the Industrial Gateway in a data center or plant. Hardware Industrial Gateway kit Software Current version of MapSense™ software. Tools and Materials The following list contains the minimum tool and material requirements installers need to bring to the job site.
  • Page 17: Installation Procedures

    ® SynapSense 2.4GHz Industrial Gateway Installation Manual Installation Procedures This chapter describes general guidelines and specific procedures for configuring and installing the Industrial Gateway. General Installation Guidelines • Be consistent. All installations should match in appearance where possible (including centering, location, method for securing extra wire, etc.) •...
  • Page 18 ® SynapSense 2.4GHz Industrial Gateway Hardware Installation Manual...
  • Page 19: Installation Preparations

    ® SynapSense 2.4GHz Industrial Gateway Installation Manual Installation Preparations Follow the activities in Table 3 to prepare for the Industrial Gateway installation. Table 3 – Installation Preparation Activities Activity Steps Unpack Kits Unpack the Industrial Gateway and accessories from boxes. Count and verify any other cables/accessories need for job.
  • Page 20: Configure Industrial Gateway

    ® SynapSense 2.4GHz Industrial Gateway Hardware Installation Manual If the Industrial Gateway configuration has been performed, proceed to Mount the Industrial Gateway. If the Industrial Gateway configuration has not been performed, or if an IP address requires changing, you will need to perform all installation activities. Configure Industrial Gateway Perform the activities in Table4 to configure the Industrial Gateway.
  • Page 21 ® SynapSense 2.4GHz Industrial Gateway Installation Manual Additional 1. Remove M12 D-coded Ethernet cable from the Industrial Industrial Gateway to configure another Gateway. Gateways 2. Plug the M12 D-coded Ethernet cable into the configuration port of the next Industrial Gateway device to be configured. 3.
  • Page 22: Mount Industrial Gateway

    Mount Industrial Gateway Perform the activities in the table below to mount the Industrial Gateway in the data center. Table 5 – Mounting the Industrial Gateway Device Activity Steps Determine 1. Before installing the Industrial Gateway, determine if the device will Industrial be installed with 3M Command Strips, Direct Mount, T-Mounting Gateway...
  • Page 23 Activity Steps 8. The Industrial Gateway’s Radio Activity( ) LED will stay green Install during wireless connection and after the connection is Gateway established during normal operation. Command 9. Remove adhesive covers from the Command Strips on the back of Strip the Industrial Gateway.
  • Page 24 Activity Steps Install The optional Industrial Gateway DIN Rail Mounting Plate allows the Industrial Industrial Gateway to be attached to standard DIN rail with a Gateway standard DIN rail clip. A standard DIN rail clip is included with the (DIN Rail Mounting Plate.
  • Page 25 Activity Steps Install The optional T-Mount Feet allow the Industrial Gateway to be directly installed to a Industrial customer supplied plate or wall. Gateway (T-Mount Feet Each T-Mount is attached to the corner of the Gateway using (1) of the included screws at the T center hole of the T-Mount foot.
  • Page 26: Final Installation Activities

    Final Installation Activities Perform the activities in Table 6 to complete the activities for the Industrial Gateway installation. Table 6 – Final Installation Activities Activity Steps Clear Installation Area Clean installation area of debris (pack- aging etc.). Dispose of trash appropriately. Proceed to Installation Inspection.
  • Page 27: Installation Inspection

    Installation Inspection This chapter describes the inspections needed to ensure installations of Industrial WSN Gateway devices are correct and functioning properly. General Inspection Inspections ensure installations are correct and Industrial Gateway devices communicate with the PLC or SynapSoft™ server. Inspect Operation and Installation Appearance 1.
  • Page 28: Integration In Plc Via Ethernet/Ip

    Integration of the Industrial WSN Gateway in the Logix Controller is performed via an Add-On Profile (AOP). 1. Create a new project in the Studio 5000 software which contains the Panduit AOP (if the release being used does not have the Panduit AOP it can be imported manually).
  • Page 29 Once the nodes are running, data can be viewed in the Device Map tab...
  • Page 30 Data in the Device Map tab will be structured as shown below: Force Data Name Value Style Description Mask Type - Gateway:I1 ('Gateway' is name given by user) + Gateway:I1.CommStatus Decimal + Gateway:I1.Diagnostics Decimal - Gateway:I1.N1 represents Node 1) Gateway:I1.N1.Shortened_MAC_ID DINT Gateway:I1.N1.SensorType Decimal...
  • Page 31: Specifications

    Depending on the node type, values 1-7 correspond to the information shown in the table below. Sensor type: Logix EZH Door Industrial 5000 EZ Node EZH Node Pressure ThermaNode Contact Node Data (0x82) (0x94) (0x13) (0x11) (0x96) (0x94) Value Door Differential Temp Temperature Temperature...
  • Page 32 Radiated Emissions IEC 61131-2:2007 Edition 3.0 EN55011 Class A, IEC/CISPR 32(2015) EN55032, IEC/CISPR 11(2015) Conducted Emissions IEC 61131-2:2007 Edition 3.0 IEC61000-6-4:2011 Edition 2.1 EN 55011 Class A, IEC/CISPR 32(2015) EN55032, IEC/CISPR 11(2015) ESD immunity IEC 61131-2:2007 Edition 3.0 IEC 61000-4-2:2008 6kV contact discharges 8kV air discharges Radiated RF immunity...
  • Page 33 UL Approval UL 61010-1, UL61010-2-201 IEEE 802.15.4 Wireless Link 2405MHz-2480MHz, +10dBm conducted TX power maximum...
  • Page 34: Appendix A - Industrial Gateway Status Led Definitions

    Appendix A – Industrial Gateway Status LED Definitions This appendix provides descriptions and the LED location for the Industrial Gateway LED(s). ® SynapSense 2.4GHz Industrial Gateway LEDs The Industrial Gateway communicates its current status via LEDs (Light Emitting Diodes); the optical windows for the LEDs are located on the top lid of the Gateway as shown below.
  • Page 35 Config Link A 100Mbps link exists in network PHY Green Flashing A 100Mbps link exists at PHY and there is IEEE Green 802.3 data activity. Ethernet 10Mbps link established in network Yellow PHY. Flashing A 10Mbps link exists at PHY and there is IEEE yellow 802.3 data activity.
  • Page 37: Appendix B - Maintenance And Troubleshooting

    Appendix B – Maintenance and Troubleshooting This appendix describes any maintenance or troubleshooting activities for the Industrial Gateway. Troubleshooting Ensure there are two open ports for each Industrial Gateway installation. Installation and testing cannot begin without these address and ports open on the configuration PC.
  • Page 38 CIDR Pre- Number of Class C Net- Total IPs Subnet Mask Usable IPs works 255.255.224.0 /19 8192 8190 255.255.192.0 /18 16,384 16,382 255.255.128.0 /17 32,768 32,766 255.255.0.0 65,536 65,534 255.254.0.0 131,072 131,070 255.252.0.0 262,144 262,142 1024 255.248.0.0 524,288 524,286 2048 255.240.0.0 1,048,576 1,048,574...
  • Page 39: General Troubleshooting

    4. If the Industrial Gateway does not respond, repeat the configuration activities, reboot the Industrial Gateway, and recheck the response. 5. Upon successful login, the Device Status screen displays with the current information. Click the Logout link to close the Remote Gateway Manager application.
  • Page 40: Panduit Technical Support

    "Auto" to match the customer's and returns to green status)? network settings. If the issue persists, the Industrial Gateway may be defective. Panduit Technical Support Severity 1 & 2 Issues: Americas: 1-866-721-5302 x86810 during normal Central Standard Time business hours EMEA: 44-1291-674-661 x22761 during normal U.K.