Siemens C) Installation Instructions Manual page 17

Electric range with threed (surround) convection
Table of Contents

Advertisement

Available languages

Available languages

Anti-tip Bracket
Attach anti-tip bracket to floor
8. Insert stripped end of WHITE wire into the CENTER lug on TOP of the ground
strap. Secure the clamping screw.
lug
wire
10. Insert stripped end of RED wire into the LEFT lug. Secure clamping screw.
11. Insert stripped end of BLACK wire into the RIGHT lug. Secure clamping
screw.
12. Tighten each clamping screw with the appropriate torque. See Table 3.
Table 3: Appropriate Torque Levels for Aluminum or Copper Wire
Gauge
6
8
13. Properly secure flexible conduit at knockout panel on range and at supply
side junction box. The wiring is now complete.
Figure 14:
Note:
DO NOT plug in range at this time.
WARNING
RANGE TIPPING HAZARD
All ranges can tip and injury could result. To prevent accidental tipping
of the range, attach it to the floor by installing the Anti-Tip Device sup-
plied.
clamping screw
Figure 9: Attaching Wire to Terminal Lug
Torque (in./lbs.)
35
25
green ground sc rew
Completed Three Wire Flexible Conduit Connecti
Installation
Torque (Nm)
3.95
2.82
on
English 13