Disinfection and sterilization guide
This guide is intended for multipatient use of the AirFit N20 / AirFit N20 for Her ResMed nasal mask in a sleep lab, clinic or hospital. If you use the mask as a single user in the home, refer to the User
Guide for cleaning instructions. This guide describes ResMed's validated procedures for cleaning, disinfection and sterilization of the mask in accordance with ISO17664.
AirFit N20 / AirFit N20 for Her
mask component
1
Thermal water bath
• Cushion
• Magnetic clip
• Multi-hole elbow and short tube
3
• Frame / headgear
1
This mask may not be available in all regions. For full details regarding the correct use of this mask, please refer to the specific User Guide.
2
If a healthcare facility requires an additional disinfection or sterilization cycle after reassembly, the number of validated cycles must be halved.
3
The multi-hole elbow and short tube are not separable.
1
High level thermal disinfection
Thermal water bath
194°F (90°C)
199.4-203°F (93-95°C)
for 1 min
for 10 min
B
C
A
2
7
3
4
5
High level chemical disinfection
CIDEX
OPA
STERRAD
Ortho-phthalaldehyde 0.55%
Short cycle
12 min soak
(boosters not required)
A
1
D
2
3
4
5
B
C
D
6
7
8
A+B+C
6
8
A+B+C+D
Clinical use only
Sterilization
100S
STERRAD
NX
Standard or
advanced cycle
Multi-hole elbow and short tube
Elbow
Side buttons
Vent
Short tube
Swivel
Frame
Cushion
Headgear
Magnetic clips
Lower headgear straps
Upper headgear straps
Frame system
Complete system
Validated number of
cycles
2
30
English
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AirFit N20 and is the answer not in the manual?

Questions and answers

Summary of Contents for ResMed AirFit N20

  • Page 1 This guide is intended for multipatient use of the AirFit N20 / AirFit N20 for Her ResMed nasal mask in a sleep lab, clinic or hospital.
  • Page 2 Validated disinfection and sterilization procedures Disassembly Disassemble the mask according to the instructions in the User Guide. Magnetic clips must be removed from the lower headgear straps. Cushion / magnetic clips Multi-hole elbow and short tube Frame / headgear ® 1.
  • Page 3 Do not iron the headgear as the material is heat sensitive and will be damaged ResMed Ltd See www.resmed.com for other ResMed locations worldwide. For patent and other intellectual property information, see www.resmed.com/ip. AirFit is a trademark and/or registered trademarks of ResMed family of 1 Elizabeth Macarthur Drive companies.

Table of Contents