No control over the machine:
- check output connections DWN and UP of the adjuster to contactors.
After pressing "Start", the machine does not stop, despite the correct dimension
entered:
- check the value of the input divider (Section 7).
The machine stops, the display shows the message "Er P":
- check the MSK-320 encoder connection to the adjuster plate; check whether the transducer
cable is broken or whether the machine head is in a position causing the activation of limit
switches; check the contactors' connections.
The dimensions are too divergent:
- auto-calibrate; check the installation of the MSK-320 sensor and its correct movement over
the magnetic tape; check the distance of the sensor along its path over the magnetic tape.
During auto-calibration, the adjuster displays the message "Auto Er P":
- measure the distance between the saws and enter the correct value to the adjuster, using the
key "Set Real size" (see Section 8), check whether the head has caused the activation of the
limit switch during the calibration movement; check the connection of the MSK-320 sensor
and its path over the tape as in the case described above regarding the message "Er P".
During manual control of the saws with the spacing reduction button, the adjuster stops
and displays the message "Set Real":
the counter value "Real size" is below zero; mistyped spacing dimension. Measure the
spacing of the saws and enter the correct value to the adjuster, using the button "Set Real
size" (see Section 8).
Operation recommendation
For having maximal good parameters of the cutting it is recommended to use auto-
calibration at least twice a week. Auto-calibration proceedings are in details described in the
point 3 of the chapter 3 "Auto-calibration (controller's checking in with technical parameters
of the sawing frame machine where its mounted)". Before starting of the operation the "Saw
Height" displayed needs to be checked and compared with the real head saw position. In case
of the any divergence it needs to be corrected according to the procedure shows in the point 4
of the chapter 3 "real saw height settings".
Do not press the keyboard using hard or sharp objects, it can cause irreversible
damages. In case of the dirty keyboard, please use only proper medium to clean it up. Please
remember to not press to hard membrane buttons. Pressing to hard of the buttons can cause
damages and eventually exchange of the hole keyboard. The controller should not be exposed
direct on getting wet with rain, water or any other fluids.
EMC Approval
Controller ANP-05 is approved and fulfil all requirements concerning electromagnetic
norms according to EMC.
The controller ANP-05 should be set up and installed according to European and domestic
norms. Responsible for adjusting the controller is person who set up the electric and control
system on the sawing frame machine. It needs to be under EMC regulations.
The controller need to be concern as a component of the sawing frame machine,
it is not a separate machine or electronic device according to European directive (machine
directive and electromagnetic compatibility directive).
The assembler of the controller ANP-05 is responsible for fulfil all those directives. Product
and equipment described within this instruction can be modify as from technical as
operational point of view. This written description – handbook manual can not be consider as
a contract.