Leister HOTWIND PREMIUM Operating Instructions Manual page 20

Hot air blower
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 16
Device Description
10
12
11
2
1
HOTWIND PREMIUM or SYSTEM
1 Power supply cord
2 Main switch with function button
3 Potentiometer for temperature (red)
4 Potentiometer for air volume (blue)
5 Heating element tube
6 Air inlet flange for stainless steel filter
7 Holder for handle
8 Four fastening screws
9 Three M5 thread inserts for fastening
for installation
Function of heating element and device protection
• If the heating element or device overheats (too hot inlet air or excess heat reside), the power supply to the
heating element will be interrupted and the working contact of the alarm relay opened.
If the heating element or device protection responds, it will be necessary to reset the HOTWIND for reasons
of safety. This occurs by pressing the function button (2)
installation).
Adjustable potentiometer
• The internal electronics regulates the maximum outlet air temperature to 650 °C.
• The reference values can be deviated from due to ambient conditions and component tolerances.
Potentiometer
Position
Heating power %
Air volume
Temperature (3680 W)
at 300 l/min
20
7
3
0
10
0
10
1
1
9
9
2
2
8
8
3
7
3
7
4
6
4
6
5
5
0
OFF
l/min
200
Environment 90
°C
4
13
8
5
6
HOTWIND SYSTEM
10 Display
11 Alarm contact
12 Interface
HOTWIND PREMIUM hand device or SYSTEM
13 Handle
14 Protective tube
1
2
3
4
10
20
30
40
270
340
410
480
150
215
275
9
for three seconds. Check inlet air (see
5
6
7
8
50
60
70
80
550
620
690
760
340
400
465
525
14
9
10
90
100
830
900
590
650

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hotwind system

Table of Contents