Leister HOTWIND PREMIUM Operating Instructions Manual page 19

Hot air blower
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 16
Technical data for interface
PREMIUM, SYSTEM
Relay output
Open loop or closed loop
Setpoint entry
Potentiometer or interface
Max. voltages
Max. currents
Max. contact resistance
Relay contact
Insulation IEC/EN 60065
Power setting function
Temperature control function
Internal potentiometer
Interface
AC 250 V, DC 30 V
AC 3 A, DC 3 A
100 m Ohm at DC 6 V / 1 A
SPST - NO
AC 2000 V (50 - 60 Hz) 1 min
setting level OFF...100 %;
1% steps
setpoint value specification
50 °C...650 °C, 5 °C steps
setpoint value OFF...100 % or
50 °C ...650 °C
setpoint value OFF...100 % or
50 °C ...650 °C
19