Checking the burner gasket and burner gauze assembly

Check burner gasket A for damage and
replace if required.
B
1. Remove electrode B.
2. Undo two Torx screws and remove
thermal insulating ring C.
3. Undo two Torx screws and remove
burner gauze assembly D with its
gasket E.
Commissioning, inspection, maintenance
Replace the burner gauze assembly if it
is damaged.
E
D
2x
4. Insert a new gasket E into the new
burner gauze assembly D and
secure.
!
(cont.)
A
C
Please note
Tighten screws far enough
to prevent damage to compo-
nents and to ensure the func-
tion is guaranteed.