Wake-Up Notification
The sensor will wake up every so often and when the case is closed to send a Wake-Up Notification to allow the life line master node controller that the sensor is
now available for any queued messages that the controller may have for the sensor. The time between Wake-Up Notifications can be configured with the Wake-
Up Notification command class to be between 1 hour and 1 week with interval steps of 200 seconds.
Configuration
The sensor has two configuration parameters. Parameter 1 configures the sensor to send or not send Basic Set commands of 0x00 to nodes in Association group
2 turning the devices off when the sensor is in a restored state i.e. the door is closed. By default the sensor does NOT send Basic Set commands of 0x00.
Parameter 2 configures the sensor to either to send or not to send Sensor Binary Report commands to Association Group 1 when the sensor is faulted and
restored. If the controller is fully compatible with the Notification Command Class thereby making the Sensor Binary Reports redundant, the controller can
disable the Sensor Binary Report Commands completely. The following table shows the values to enable and disable the two configuration parameters.
Configuration Set Values
Parameter Number: 1
Size: 1
Configuration Value: 0x00
Parameter Number: 1
Size: 1
Configuration Value: 0xFF
Parameter Number: 2
Size: 1
Configuration Value: 0x00
Parameter Number: 2
Size: 1
Configuration Value: 0xFF
© 2015 Ecolink Intelligent Technology Inc.
Effect
(Default) Sensor does NOT send Basic Sets to Node
IDs in Association Group 2 when the sensor is
restored ( i.e. Door Closed ).
Sensor sends Basic Sets of 0x00 to nodes in
Association Group2 when sensor is restored.
(Default) Sensor sends Sensor Binary Reports when
sensor is faulted and restored for backwards
compatibility in addition to Notification Reports.
Sensor will send only Notification Reports and NOT
Sensor Binary Reports when the sensor is faulted
and restored.