SENSOR
CONDITION
Door Open
Door Close
Sensor Case Removed
Sensor Case Fastened
Battery Level Dipped Below 2.6v
© 2015 Ecolink Intelligent Technology Inc.
COMMAND CLASS and VALUE
Notification Report of Access Control
(0x06), Door is open (0x16)
Sensor Binary Report of 0xFF
Sensor Type: 0xFF
Basic set of 0xFF (On)
Notification Report of Access Control
(0x06), Door is closed (0x17)
Sensor Binary Report of 0x00
Sensor Type: 0xFF
Basic Set of 0x00 (Off)
By factory default this feature is disabled
and must be enabled via Configuration
Command Class.
Notification Report of Home Security
(0x07), Tampering product cover
removed (0x03)
Wake-Up Notification
Notification Report of Power
Management (0x08), Replace battery
now (0x0B)
ASSOCIATION GROUP
Yes via Notification Set of notificationType
(0x06) and status of 0x00: This type of
1
0xFF: This type of notification turned on
Command Class Parameter Number: 2
1
Size: 1
A Configuration Value: 0xFF (On) / 0x00
(Off)
2
Yes via Notification Set of notificationType
(0x06) and status of 0x00: This type of
1
0xFF: This type of notification turned on
Yes via Configuration Command Class
Parameter Number: 2
1
Size: 1
A Configuration Value: 0xFF (On) / 0x00
(Off)
2
Yes via Configuration Command Class
Parameter Number: 1
Size: 1
A Configuration Value: 0xFF (On) / 0x00
(Off) Parameter Number: 2
Yes via Notification Set of notificationType
(0x07) and status of 0x00: This type of
1
0xFF: This type of notification turned on
1
Yes via Wake-Up Notification Command
Class
Yes via Notification Set of notificationType
(0x08) and status of 0x00: This type of
1
0xFF: This type of notification turned on
CONFIGURABLE?
notification turned off
Yes via Configuration
No
notification turned off
notification turned off
notification turned off
PN TLT-ZWAVE2.5 R1.03