Mitsubishi Electric City Multi PURY-M200YNW-A1 Data Book page 11

Air conditioning systems
Hide thumbs Also See for City Multi PURY-M200YNW-A1:
Table of Contents

Advertisement

1. SPECIFICATIONS
Model
Power source
Cooling capacity
(Nominal)
Power input
Current input
EER
Temp. range of
Indoor
cooling
*3 Outdoor
Heating capacity
(Nominal)
Power input
Current input
COP
Temp. range of
Indoor
heating
*3 Outdoor
Indoor unit
Total capacity
connectable
Model/Quantity
Sound pressure level (measured in anechoic room) *4 dB <A>
Sound power level (measured in anechoic room) *4
Refrigerant
High pressure
piping diameter
Low pressure
FAN
Type x Quantity
Air flow rate
Control, Driving mechanism
Motor output
*5 External static press.
Compressor
Type
Manufacture
Starting method
Motor output
Case heater
Lubricant
External finish
External dimension H x W x D
Protection devices
High pressure protection
Inverter circuit (COMP./FAN)
Compressor
Fan motor
Refrigerant
Type x original charge
Control
Net weight
Heat exchanger
HIC circuit (HIC: Heat Inter-Changer)
Defrosting method
Drawing
External
Wiring
Standard attachment
Document
Accessory
Optional parts
Remarks
Notes:
1.Nominal cooling conditions (subject to JIS B8615-2)
Indoor: 27°CD.B./19°CW.B. (81°FD.B./66°FW.B.), Outdoor: 35°CD.B./24°CW.B. (95°FD.B./75°FW.B.)
Pipe length: 7.5 m (24-9/16 ft.), Level difference: 0 m (0 ft.)
2.Nominal heating conditions (subject to JIS B8615-2)
Indoor: 20°CD.B. (68°FD.B.), Outdoor: 7°CD.B./6°CW.B. (45°FD.B./43°FW.B.)
Pipe length: 7.5 m (24-9/16 ft.), Level difference: 0 m (0 ft.)
3.-5°CD.B. (23°FD.B.)/-6°CW.B. (21°FW.B.) to 21°CD.B. (70°FD.B.)/15.5°CW.B. (60°FW.B.)
with cooling/heating mixed operation.
4.Cooling mode/Heating mode
5.External static pressure option is available (30 Pa, 60 Pa, 80 Pa/3.1 mmH
Consult your dealer about the specification when setting External static pressure option.
6.R32 is flammable, and certain restrictions apply to the installation of units.
When installing new units, moving the existing units, or changing the layout of the room,
ensure that installation restrictions are observed.
For detail, refer to the section in the Databook on installation restrictions.
MEES18K068
*1 kW
kcal/h
BTU/h
kW
A
kW/kW
W.B.
D.B.
*2 kW
kcal/h
BTU/h
kW
A
kW/kW
D.B.
W.B.
dB <A>
mm (in.)
mm (in.)
3
m
/min
L/s
cfm
kW
kW
kW
mm
in.
kg (lbs)
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be
referred to the Installation Manual.
Due to continuing improvement, above specifications may be subject to change without notice.
O, 6.1 mmH
O, 8.2 mmH
2
2
PURY-EM200YNW-A1 (-BS)
3-phase 4-wire 380-400-415 V 50/60 Hz
22.4
20,000
76,400
5.13
8.6-8.2-7.9
4.36
15.0~24.0°C (59~75°F)
-5.0~52.0°C (23~126°F)
25.0
21,500
85,300
6.23
10.5-9.9-9.6
4.01
15.0~27.0°C (59~81°F)
-20.0~15.5°C (-4~60°F)
50~150% of outdoor unit capacity
WP10~125, W10~125/1~30
59.0/59.0
76.0/78.0
15.88 (5/8) Brazed
19.05 (3/4) Brazed
Propeller fan x 1
170
2,833
6,003
Inverter-control, Direct-driven by motor
0.92 x 1
0 Pa (0 mmH
O)
2
Inverter scroll hermetic compressor
AC&R Works, MITSUBISHI ELECTRIC CORPORATION
Inverter
4.5
- (- V)
MEL46EH
Pre-coated galvanized steel sheets (+powder coating for -BS type)
<MUNSELL 5Y 8/1 or similar>
1,858 (1,798 without legs) x 920 x 740
73-3/16 (70-13/16 without legs) x 36-1/4 x 29-3/16
High pressure sensor, High pressure switch at 4.15 MPa (601 psi)
Over-heat protection, Over-current protection
-
-
R32 x 5.2 kg (12 lbs)
HBC controller
231 (510)
Salt-resistant cross fin & aluminium tube
-
Auto-defrost mode (Reversed refrigerant cycle, Hot gas)
WKL94T601
WKE94G769
Installation Manual
-
Main HBC controller: CMB-WM108,1016V-AA
Sub HBC controller: CMB-WM108,1016V-AB
O).
2
R2-Series
Unit converter
BTU/h
=kW x 3,412
3
cfm
=m
/min x 35.31
lbs
=kg/0.4536
*Above specification data is
subject to rounding variation.
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents