Air-conditioners for building application, outdoor unit

Advertisement

Quick Links

Air-Conditioners For Building Application
OUTDOOR UNIT
PURY-P-YMF-C
INSTALLATION MANUAL
For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.
INSTALLATIONSHANDBUCH
Zum sicheren und ordnungsgemäßen Gebrauch der Klimageräte das Installationshandbuch gründlich durchlesen.
MANUEL D'INSTALLATION
Veuillez lire le manuel d'installation en entier avant d'installer ce climatiseur pour éviter tout accident et vous assurer d'une utilisation correcte.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, leggere attentamente questo manuale di installazione prima di installare il condizionatore d'aria.
INSTALLATIEHANDLEIDING
Voor een veilig en juist gebruik moet u deze installatiehandleiding grondig doorlezen voordat u de airconditioner installeert.
MANUAL DE INSTALAÇÃO
Para segurança e utilização correctas, leia atentamente este manual de instalação antes de instalar a unidade de ar condicionado.
E°XEIPI¢IO O¢H°IøN E°KATA™TA™H™
°È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙ ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ÂÁηٿÛÙ·Û˘ ÚÈÓ ·Ú¯›ÛÂÙ ÙËÓ
ÂÁηٿÛÙ·ÛË Ù˘ ÌÔÓ¿‰·˜ ÎÏÈÌ·ÙÈÛÌÔ‡.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для осторожного и правильного использования прибора необходимо тщательно ознакомиться с данным руководством по
установке до выполнения установки кондиционера.
MONTAJ ELK‹TABI
Emniyetli ve do¤ru biçimde nas›l kullan›laca¤›n› ö¤renmek için lütfen klima cihaz›n› monte etmeden önce bu elkitab›n› dikkatle okuyunuz.

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric CITY MULTI PURY-P400YMF-C

  • Page 1 Air-Conditioners For Building Application OUTDOOR UNIT PURY-P-YMF-C INSTALLATION MANUAL For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH Zum sicheren und ordnungsgemäßen Gebrauch der Klimageräte das Installationshandbuch gründlich durchlesen. MANUEL D’INSTALLATION Veuillez lire le manuel d’installation en entier avant d’installer ce climatiseur pour éviter tout accident et vous assurer d’une utilisation correcte. MANUAL DE INSTALACIÓN Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de aire acondicionado.
  • Page 2 [Fig. 4.0.1] <A> = > <A> Top view = > <B> Side view <C> When there is little space up to an obstruction A: Front = > = > B: No restrictions on wall height (left 1000 = > and right) C: Air outlet guide (Procured at the site) <B>...
  • Page 3 (*Note1) [Fig. 7.2.1] (mm) Å High press pipe ı Low press pipe PURY-P400 ø25.4 ø34.93 PURY-P500 ø25.4 ø34.93 ø 25.4 (Flange) Ç Connection of outdoor ø 19.05 (Flare) unit/BC controller ø 28.58 (Frange) (mm) No.6 Î Total capacity of indoor units ‰...
  • Page 4 [Fig. 9.2.1] A: Power source [Fig. 8.4.1] B: Transmission line L1 L2 L3 N M1M2 M1M2 S [Fig. 9.3.1] A: Steel wire B: Piping C: Asphaltic oily mastic or asphalt D: Heat insulation material A (51) E: Outer covering B (52) (01) (02)
  • Page 5 [Fig. 9.4.1] A: Switch (Breakers for Wiring and Current Leakage) B: Outdoor Unit C: BC Controller (master) 3 N~380 - 450 V C: BC Controller (slave) D: Pull Box , N, PE E: Indoor Unit ~220 - 240 V L, N, PE...
  • Page 6: Table Of Contents

    Contents 1. Safety precautions ..................6 7.1. Caution ..................8 1.1. Before installation and electric work .......... 6 7.2. Refrigerant piping system ............9 1.2. Precautions for devices that use R407C refrigerant ....6 8. Additional Refrigerant Charge ..............9 1.3.
  • Page 7: Before Getting Installed

    • Do not use a refrigerant other than R407C. • Install an leak circuit breaker, as required. - If another refrigerant (R22, etc.) is used, the chlorine in the refrigerant may - If an leak circuit breaker is not installed, electric shock may result. cause the refrigerator oil to deteriorate.
  • Page 8: Space Required Around Unit

    4. Space required around unit [Fig. 4.0.1] (P.2) (4) When unit is surrounded by walls <A> Top view <B> Side view Note: <C> When there is little space up to an obstruction • Wall heights (H) of the front and the back sides shall be within overall A Front height of unit.
  • Page 9: Refrigerant Piping System

    6 The City Multi Series R2 will stop due to an abnormality due to excessive or • Do not use the tools shown below used with conventional refrigerant. (For R407C models) insufficient coolant. At such a time, always properly charge the unit. When servicing, always check the notes concerning pipe length and amount of addi- (Gauge manifold, charge hose, gas leak detector, check valve, refriger- ant charge base, vacuum gauge, refrigerant recovery equipment)
  • Page 10: Airtight Test, Evacuation, And Refrigerant Charging

    [Fig. 8.2.2] (P.3) Tightening angle standard: <A> [Ball valve (low press side)] Pipe diameter (mm) Tightening angle (°) (This figure shows the valve in the fully open state.) ø6.35, ø9.52 60 to 90 ø12.7, ø15.88 30 to 60 <B> [Ball valve (high press side)] ø19.05 20 to 35 A Valve stem...
  • Page 11: Thermal Insulation Of Refrigerant Piping

    8.4. Thermal insulation of refrigerant piping [Fig. 8.4.2] (P.4) A Liquid pipe B Gas pipe C Electric wire Be sure to give insulation work to refrigerant piping by covering liquid pipe and gas D Finishing tape E Insulater pipe separately with enough thickness heat-resistant polyethylene, so that no gap [Fig.
  • Page 12 Example of a group operation system with multiple outdoor units (Shielding wires and address setting are necessary.) <Examples of Transmission Cable Wiring> [Fig. 9.3.1] M-NET Remote Controller (P.4) [Fig. 9.3.2] MA Remote Controller (P.4) [Fig. 9.3.3] Transmission booster unit (P.4) A Group 1 B Group 4 C Group 5...
  • Page 13: Wiring Of Main Power Supply And Equipment Capacity

    Remote controller cable length: r • 10 m (0.3 to 1.25 mm If the length exceeds 10 m, use 1.25 mm shielded cable and calculate the length of that portion (L and L ) as within the total extended length and the longest remote length. 9.4.
  • Page 14 This product is designed and intended for use in the residential, commer- cial and light-industrial environment. • Low Voltage Directive 73/23/EEC The product at hand is • Electromagnetic Compatibility Directive 89/ based on the following EU regulations: 336/EEC Please be sure to put the contact address/telephone number on this manual before handing it to the customer.