Siemens CP 1625 Operating Instructions Manual page 24

Simatic industrial pc. pc-profinet irt
Table of Contents

Advertisement

Technical specifications
Construction
Module format
Dimensions (H x W x D) in mm
Weight
Space required
Requirements for the external power supply
Electrical isolation
Voltage range
CP 1625 current consumption with the PC turned off
NOTICE
Damage to the IPC and/or the CP 1625Dev
If you connect a plugged CP 1625Dev communications processor to a 24 V DC power
supply, this can result in undefined states.
Damage to the IPC and/or the CP 1625Dev communications processor can occur as a
consequence.
Do not connect a 24 V DC power supply to a plugged CP 1625Dev communications
processor.
This product is intended for delivery with a UL-listed power supply unit designated as Class 2
with 24 V DC, 1 A (rated values) and a recommended ambient temperature of 45 °C.
Power supply
Plug-in connector FMC 1.5 / 2-ST-3.81 (ships
with the product) or compatible
External supply
If supplied from a separate source, this must meet the requirements to comply with NEC
Class 2.
24
WARNING
PC card, short PCIe format
Standard height
half length
111.2 x 21.6 x 167.15
110 g
PCIe slot
required
19.2 V DC to 28.8 V DC
Approx. 0.25 A at 24 V
Contact clearance: 3.81 mm
Cable cross section: 0.2 mm
Operating Instructions, 04/2018, A5E43075902-AA
... 1.5 mm
2
2
CP 1625 / CP 1625Dev

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp 1625dev

Table of Contents