Fig. 5 - Removing slotted knockouts.
Fig. 6 - Insert strain relief bushing.
3. Refer to the following section for type of wiring
connections (standard wire push-in terminals or female
receptacle).
WIRING CONNECTIONS
When connecting cable or conduit to this controller,
use care to avoid strain on the control case.
Connections can be made to standard wire push-in
terminals or female receptacles for 1/4 in. (6.4 mm)
male flag connectors on both the fan and limit
switches (Fig. 8).
FOR STANDARD WIRE PUSH-IN TERMINALS
Connect wires to the terminals as follows:
1. Use Nos. 14,16, or 18 solid wire or Nos. 14 or 16
stranded wire, depending on electrical requirement.
2. Strip insulation from wires the distance shown by
the strip gauge on the controller.
3. Solid wire may be inserted directly into the
terminal holes. If stranded wire is used, insert a small
screwdriver into the slot next to the terminal. Push
screwdriver in and hold while inserting wire into
terminal (Fig. 8). Remove screwdriver. If stranded wire
is solder-dipped, it can be pushed directly into
terminal holes.
Fig. 7 - Closing the strain relief bushing.
FOR FEMALE RECEPTACLES -
It is recommended that the female receptacles be
used for wiring accessory equipment; i.e.,
electronic air cleaner, humidifier, etc.
Connect wires to the receptacles as follows:
1. Use Nos. 14 to 18 size wire, depending on
electrical requirement.
2. Attach 1/4 in. (6.4 mm) male flag connector to
each wire. Two male connectors with leadwires are
supplied.
3. Push male flag connector directly into the
female receptacle. Make sure that the flag is forced
to the bottom of cavity and wire is in the channel
(Fig. 8).
Make certain all wires are clear of rotating scaleplate.
WIRING GUARD
FEMALE
RECEPTACLE FOR
CONNECTION OF
1/4 IN. (6.4 MM)
MALE SPADE
TERMINAL (4)
STANDARD
WIRE PUSH IN
CONNECTORS
(4)
FAN
PUSH MAN
PULL AUTO
REMOVABLE
BRASS
JUMPER
Fig. 8 - Location of wiring connections.
3
IMPORTANT
CAUTION
DO NOT ROTATE HOLD
DIAL WHEN SETTING
FAN LIMIT
150
LIMIT
LEADWIRE WITH 1/4
BOTTOM OF CAVITY)
69-0117-3
TO RELEASE
STANDARD WIRE -
PUSH SCREW
DRIVER IN AND
PULL WIRE OUT
STANDARD
WIRE TO
CONTROLLED
EQUIPMENT
IN. (6.4 MM) MALE
SPADE TERMINAL
(FORCE SPADE TO
11,204B