4. Remove the transportation protection (G) between the
smoke deflectors before start using the stove.
Røgvender støtte
Name:
Weight:
N/A
Area:
A ( 1 : 4 )
5. Place the middle baffle (H) on the pins (I).
10
18-10-17
Date:
Constructed/Changed by:
N/A
SCAN A/S
DK-5492 Vissenbjerg©
H
I
4.2 Chimney and flue pipe
•
The fireplace must only be connected to a chimney and
flue pipe approved for solid fuel fireplaces with flue gas
temperatures as specified in «2.0 Technical Data»
•
The specified distance to flammable materials, applies to
this stove
G
•
The distance of the flue pipe to combustible materials
must also be observed
•
The cross-section of the chimney must be designed to
fit the fireplace. Use «2.0 Technical Data» calculate the
correct chimney cross-section
•
The chimney must be connected in accordance with the
installation instructions of the chimney supplier
•
Before a hole is made in the chimney, the product should
be test-mounted in order to correctly mark the position of
the fireplace and the hole in the chimney. See fig. 1 for
minimum dimensions
•
The flue pipe must be CE-certified. Please note that the
distance to combustible materials can be defined by the
flue pipe's distance to combustible materials.
•
With a rear outlet, use a flue pipe bend with a sweep
hatch to allow sweeping
•
Please note that it is extremely important for connections
to have a degree of flexibility. This is to prevent any
movement in the installation leading to the formation of
cracks
•
For recommended chimney draught, see «2.0 Technical
Data». For flue pipe dimension see «2.0 Technical Data»
NB! The minimum recommended chimney length is 3.5 m
from the flue pipe insert. If the draught is too strong, a flue pipe
damper can be installed and used to reduce the draught.
A ( 1 : 4 )
Drawing
90230160
number:
jm
A