4. Remove the transportation protection (G) between the
smoke deflectors before start using the stove.
Røgvender støtte
Name:
Weight:
N/A
Area:
A ( 1 : 4 )
5. Place the middle baffle (H) on the pins (I).
10
18-10-17
Date:
Constructed/Changed by:
N/A
SCAN A/S
DK-5492 Vissenbjerg©
H
I
4.2 Chimney and flue pipe
The fireplace must only be connected to a chimney and
flue pipe approved for solid fuel fireplaces with flue gas
temperatures as specified in «2.0 Technical Data»
The specified distance to flammable materials, applies to
this stove
G
The distance of the flue pipe to combustible materials
must also be observed
The cross-section of the chimney must be designed to
fit the fireplace. Use «2.0 Technical Data» calculate the
correct chimney cross-section
The chimney must be connected in accordance with the
installation instructions of the chimney supplier
Before a hole is made in the chimney, the product should
be test-mounted in order to correctly mark the position of
the fireplace and the hole in the chimney. See fig. 1 for
minimum dimensions
The flue pipe must be CE-certified. Please note that the
distance to combustible materials can be defined by the
flue pipe's distance to combustible materials.
With a rear outlet, use a flue pipe bend with a sweep
hatch to allow sweeping
Please note that it is extremely important for connections
to have a degree of flexibility. This is to prevent any
movement in the installation leading to the formation of
cracks
For recommended chimney draught, see «2.0 Technical
Data». For flue pipe dimension see «2.0 Technical Data»
NB! The minimum recommended chimney length is 3.5 m
from the flue pipe insert. If the draught is too strong, a flue pipe
damper can be installed and used to reduce the draught.
A ( 1 : 4 )
Drawing
90230160
number:
jm
A