Storage server with intel xeon d processor, up to 128 gb ddr4 ram, quad gbe port, pcie 3.0 x8/x4 slots, 2u rack mount chassis, 450 w redundant psu, rohs (60 pages)
Storage server with dual intel xeon e5 processor, up to 1tb ddr ram. (63 pages)
Summary of Contents for IEI Technology IBX-660 series
Page 1
IBX-660 Industrial Edge Storage Server IBX-660 Industrial server MODEL: MODEL: IBX-660 Series 4-bay Industrial Data Storage PC for Smart Factory and Harsh Environment User Manual Page i Rev. 1.00 – April 25, 2018...
Page 2
IBX-660 Industrial Edge Storage Server Revision Date Version Changes April 25, 2018 1.00 Initial release Page ii...
Page 3
IBX-660 Industrial Edge Storage Server Copyright COPYRIGHT NOTICE The information in this document is subject to change without prior notice in order to improve reliability, design and function and does not represent a commitment on the part of the manufacturer. In no event will the manufacturer be liable for direct, indirect, special, incidental, or consequential damages arising out of the use or inability to use the product or documentation, even if advised of the possibility of such damages.
Page 4
IBX-660 Industrial Edge Storage Server Manual Conventions WARNING Warnings appear where overlooked details may cause damage to the equipment or result in personal injury. Warnings should be taken seriously. CAUTION Cautionary messages should be heeded to help reduce the chance of losing data or damaging the product.
IBX-660 Industrial Edge Storage Server Table of Contents 1 INTRODUCTION ......................1 1.1 O ........................2 VERVIEW 1.2 M ....................2 ODEL ARIATIONS 1.3 F ........................3 EATURES 1.4 F ......................3 RONT ANEL 1.5 R ....................... 4 ANEL 1.6 B ......................
Page 6
IBX-660 Industrial Edge Storage Server 4.1 I ......................27 NTRODUCTION 4.1.1 Starting Setup ....................27 4.1.2 Using Setup ...................... 27 4.1.3 Getting Help ..................... 28 4.1.4 BIOS Menu Bar ....................28 4.2 M ........................29 4.3 A ....................... 30 DVANCED 4.3.1 Hardware Monitor ...................
Page 7
IBX-660 Industrial Edge Storage Server List of Figures Figure 1-1: IBX-660 Industrial Edge Storage Server ..............2 Figure 1-2: Front Panel ........................3 Figure 1-3: Rear Panel ........................4 Figure 1-4: Bottom Surface ......................5 Figure 1-5: Dimensions (mm/inch) ....................8 Figure 3-1: Bottom Panel Removal .....................
Page 8
IBX-660 Industrial Edge Storage Server List of Tables Table 1-1: IBX-660 Model Variations ..................... 2 Table 1-2: Hardware Specifications ....................7 Table 2-1: Package List ........................ 11 Table 4-1: BIOS Navigation Keys ....................28 Page viii...
IBX-660 Industrial Edge Storage Server 1.1 Overview Figure 1-1: IBX-660 Industrial Edge Storage Server The 4-bay compact IBX-660 is powered by an industrial-grade quad-core 1.91 GHz Intel® Atom™ E3845 processor, DDR3L RAM configurations, and two gigabit LAN ports to deliver remarkable speeds. Engineered with a rugged steel body and no moving parts, this small form factor IBX-660 server is capable of operating under wide temperatures from -40°C to +50°C (-40°F ~ 122°F)
IBX-660 Industrial Edge Storage Server 1.3 Features The IBX-660 has the following features RoHS compliant design Fanless system 1.91GHz Intel® Atom™ E3845 quad-core processor Supports DDR3L SO-DIMM memory Dual GbE LAN for high speed network applications ...
IBX-660 Industrial Edge Storage Server 1.5 Rear Panel The rear panel of the IBX-660 provides access to the following external I/O connectors. 1 x 12 V DC power input jack 1 x 9 V ~ 36 V DC power input terminal block (4-pin) ...
IBX-660 Industrial Edge Storage Server 1.6 Bottom Surface WARNING: Never remove the bottom access panel from the chassis while power is still being fed into the system. Before removing the bottom access panel, make sure the system has been turned off and all power connectors unplugged.
IBX-660 Industrial Edge Storage Server 1.7 Hardware Specifications The hardware specifications for the IBX-660 are listed below. IBX-660 CPU (SoC) 22nm Intel® Atom™ E3845 quad core processor (1.91 GHz) Memory Slot 2 x 204-pin DDR3L SO-DIMM slots (system max. 8 GB) *IBX-660-8G model is preinstalled with 8 GB (two 4 GB) memory *For dual-DIMM configurations, you must use a pair of identical DDR3L modules.
IBX-660 Industrial Edge Storage Server Power Supply Power 1: DC power jack, external power adaptor, 12 V, 90 W, 100 V–240 V input Power 2: 4-pin terminal block, 9 V–36 V DC Power Consumption 40 W (Intel® Atom® E3845 CPU with 8 GB 1600 MHz DDR3L memory and four 2.5"...
IBX-660 Industrial Edge Storage Server 1.8 Dimensions The dimensions of the IBX-660 are listed below and shown in Figure 1-5. Figure 1-5: Dimensions (mm/inch) Page 8...
IBX-660 Industrial Edge Storage Server 2.1 Unpacking To unpack the IBX-660, follow the steps below: Step 1: Use box cutters, a knife or a sharp pair of scissors that seals the top side of the external (second) box. Step 2: Open the external (second) box.
Table 2-1: Package List 2.3 Optional Items The following are optional components which may be separately purchased: Item and Part Number Image OS Image with Windows 10 IoT Enterprise Entry 64-bit for IBX-660 series, with DVD-ROM, RoHS (P/N: IBX-660-W10E64-E-R10) Page 11...
This reduces the possibility of ESD damaging the IBX-660. 3.2 Installation Precautions CAUTION: The IBX-660 series has more than one power supply connection point. To reduce the risk of electric shock, disconnect all power sources before installing or servicing the IBX-660 series.
IBX-660 Industrial Edge Storage Server Read the user manual: The user manual provides a complete description of the IBX-660, installation instructions and configuration options. DANGER! Disconnect Power: Power to the IBX-660 must be disconnected during the installation process. Failing to disconnect the power may cause severe injury to the body and/or damage to the system.
IBX-660 Industrial Edge Storage Server 3.4 SO-DIMM Installation (Optional) WARNING: Using incorrectly specified SO-DIMM may cause permanently damage the IBX-660. Please make sure the purchased SO-DIMM complies with the memory specifications of the IBX-660. To install a SO-DIMM memory module into a SO-DIMM socket, please follow the steps below.
IBX-660 Industrial Edge Storage Server Step 2: Slide the memory module to the slot at a 45-degree angle (approximately) and press the memory module down until it clips into place. Ensure the memory module sits properly with the clips in place. Figure 3-2: SO-DIMM Installation NOTE: Always ensure that a memory module is installed in the primary slot...
IBX-660 Industrial Edge Storage Server Step 3: Close the bottom cover and fasten the screws (refer to Step 1 for screw positions). 3.5 Hard Drive Installation NOTE: Before installing hard drives, ensure the solid disk drives (SSDs) that you use are compatible with the IBX-660. Four 2.5”...
IBX-660 Industrial Edge Storage Server Step 2: Remove the hard drive tray (Figure 3-4). Figure 3-4: HDD Tray Removal Step 3: Attach the drive to the tray and secure the four screws in the back of the drive tray (Figure 3-5). Figure 3-5: HDD Tray Installation Page 18...
IBX-660 Industrial Edge Storage Server Step 4: Insert the drive tray into the IBX-660 all the way to the end (Figure 3-6). Figure 3-6: HDD Installation Step 5: Repeat Step 2 Step 4 to install the remaining drives. Please follow the HDD Sequence shown in Step 2 to do so.
IBX-660 Industrial Edge Storage Server WARNING: Users are strongly recommended to turn OFF the IBX-660 before replacing the hard drive to reduce the risk of electric shock. CAUTION: IEI disclaims any responsibility for product damage/malfunction or data loss/recovery due to misuse or improper installation of hard disks in any occasions for any reasons.
IBX-660 Industrial Edge Storage Server Figure 3-8: Mounting Bracket Installation Step 4: Drill holes in the intended installation surface. Step 5: Align the mounting holes in the sides of the mounting brackets with the predrilled holes in the mounting surface. Step 6: Insert four retention screws, two in each bracket, to secure the system to the wall.
IBX-660 Industrial Edge Storage Server The system is securely mounted 3.7.2 Terminal Block Pinouts The IBX-660 has a 9 V–36 V power input terminal block. The terminal block pinouts are shown in Figure 3-9. Figure 3-9: Terminal Block Pinouts 3.7.3 Power-on Procedure To power-on the IBX-660 please follow the steps below: Step 1:...
IBX-660 Industrial Edge Storage Server Step 3: Once turned on, the status LED indicator should turn to green (Figure 3-11). Figure 3-11: Power LED Step 4: To turn off the IBX-660, press the power button for 1.5 seconds. To force turn off, press the power button for 5 seconds. 3.8 Available Drivers All the drivers for the IBX-660 are available on IEI Resource Download Center (https://download.ieiworld.com).
IBX-660 Industrial Edge Storage Server 3.8.1 Driver Download To download drivers from IEI Resource Download Center, follow the steps below. Step 1: Go to https://download.ieiworld.com. Type IBX-660IBX-660IBX-660 and press Enter. Step 2: All product-related software, utilities, and documentation will be listed. You can choose Driver to filter the result.
Page 33
IBX-660 Industrial Edge Storage Server NOTE: To install software from the downloaded ISO image file in Windows 8, 8.1 or 10, double-click the ISO file to mount it as a virtual drive to view its content. On Windows 7 system, an additional tool (such as Virtual CD-ROM Control Panel from Microsoft) is needed to mount the file.
IBX-660 Industrial Edge Storage Server 4.1 Introduction The BIOS is programmed onto the BIOS chip. The BIOS setup program allows changes to certain system settings. This chapter outlines the options that can be changed. NOTE: Some of the BIOS options may vary throughout the life cycle of the product and are subject to change without prior notice.
IBX-660 Industrial Edge Storage Server Function Decrease the numeric value or make changes Page up Move to the next page Page down Move to the previous page Main Menu – Quit and do not save changes into CMOS Status Page Setup Menu and Option Page Setup Menu -- Exit current page and return to Main Menu F1 key General help, only for Status Page Setup Menu and Option...
IBX-660 Industrial Edge Storage Server 4.2 Main The Main BIOS menu (BIOS Menu 1) appears when the BIOS Setup program is entered. The Main menu gives an overview of the basic system information. Aptio Setup Utility – Copyright (C) 2013 American Megatrends, Inc. Main Advanced Chipset...
IBX-660 Industrial Edge Storage Server 4.3 Advanced Use the Advanced menu (BIOS Menu 2) to configure the CPU and peripheral devices through the following sub-menus: Aptio Setup Utility – Copyright (C) 2013 American Megatrends, Inc. Main Advanced Chipset Security Boot Save &...
IBX-660 Industrial Edge Storage Server 4.3.1 Hardware Monitor The Hardware Monitor menu (BIOS Menu 3) displays operating temperature and voltage. Aptio Setup Utility – Copyright (C) 2013 American Megatrends, Inc. Advanced PC Health Status CPU Temperature : +25 C VIN1 : +0.984 V VIN2 : +2.128 V...
IBX-660 Industrial Edge Storage Server 4.3.2 CPU Configuration Use the CPU Configuration menu (BIOS Menu 4) to view detailed CPU specifications. Aptio Setup Utility – Copyright (C) 2013 American Megatrends, Inc. Advanced CPU Configuration Intel(R) Atom(TM) CPU E3845 @ 1.91GHz CPU Signature 30679 Microcode Patch...
IBX-660 Industrial Edge Storage Server 4.3.3 USB Configuration Use the USB Configuration menu (BIOS Menu 5) to read USB configuration information. Aptio Setup Utility – Copyright (C) 2013 American Megatrends, Inc. Advanced USB Configuration USB Module Version 8.11.02 USB Devices: --------------------- : Select Screen 1 Keyboard, 2 Hubs...
IBX-660 Industrial Edge Storage Server 4.4 Chipset Use the Chipset menu (BIOS Menu 6) to configure chipset component options. Aptio Setup Utility – Copyright (C) 2013 American Megatrends, Inc. Main Advanced Chipset Security Boot Save & Exit DVMT Pre-Allocated [64M] Select DVMT 5.0 DVMT Total Gfx Mem [256MB]...
Page 43
IBX-660 Industrial Edge Storage Server 448M DVMT Total Gfx Mem [Max] Use the DVMT Total Gfx Mem option to specify the maximum amount of memory that can be allocated as graphics memory. Configuration options are listed below. 128MB ...
IBX-660 Industrial Edge Storage Server 4.5 Security Use the Security menu (BIOS Menu 7) to set system and user passwords. Aptio Setup Utility – Copyright (C) 2013 American Megatrends, Inc. Main Advanced Chipset Security Boot Save & Exit Password Description Set Administrator Password If ONLY the Administrator’s password is set,...
IBX-660 Industrial Edge Storage Server 4.6 Boot Use the Boot menu (BIOS Menu 8) to configure system boot options. Aptio Setup Utility – Copyright (C) 2013 American Megatrends, Inc. Main Advanced Chipset Security Boot Save & Exit Boot Configuration Select the keyboard Bootup NumLock State [On] NumLock state...
IBX-660 Industrial Edge Storage Server Quiet Boot [Enabled] Use the Quiet Boot BIOS option to select the screen display when the system boots. Normal POST messages displayed Disabled OEM Logo displayed instead of POST messages Enabled EFAULT 4.7 Save &...
Page 47
IBX-660 Industrial Edge Storage Server Restore Defaults Use the Restore Defaults option to load the optimal default values for each of the parameters on the Setup menus. F3 key can be used for this operation. Save as User Defaults Use the Save as User Defaults option to save the changes done so far as user defaults.
IBX-660 Industrial Edge Storage Server WARNING: The following instructions should only be performed by an authorized and trained technician. Before starting, please ensure that you turn off the IBX-660, disconnect the power adaptor, network cable(s), and also remove any other device/cable that is attached to the server.
IBX-660 Industrial Edge Storage Server Appendix Regulatory Compliance Page 42...
Page 51
IBX-660 Industrial Edge Storage Server DECLARATION OF CONFORMITY This equipment is in conformity with the following EU directives: EMC Directive 2004/108/EC Low-Voltage Directive 2006/95/EC RoHS II Directive 2011/65/EU If the user modifies and/or install other devices in the equipment, the CE conformity declaration may no longer apply.
Page 52
IBX-660 Industrial Edge Storage Server Español [Spanish] IEI Integration Corp declara que el equipo cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. Ελληνική [Greek] IEI Integration Corp ΔΗΛΩΝΕΙ ΟΤΙ ΕΞΟΠΛΙΣΜΟΣ ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ...
Page 53
IBX-660 Industrial Edge Storage Server Româna [Romanian] IEI Integration Corp declară că acest echipament este in conformitate cu cerinţele esenţiale şi cu celelalte prevederi relevante ale Directivei 1999/5/CE. Slovensko [Slovenian] IEI Integration Corp izjavlja, da je ta opreme v skladu z bistvenimi zahtevami in ostalimi relevantnimi določili direktive 1999/5/ES.
Page 54
IBX-660 Industrial Edge Storage Server FCC WARNING This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation.
IBX-660 Industrial Edge Storage Server WARNING: The precautions outlined in this chapter should be strictly followed. Failure to follow these precautions may result in permanent damage to the IBX-660. B.1 Safety Precautions Please follow the safety precautions outlined in the sections that follow: B.1.1 General Safety Precautions Please ensure the following safety precautions are adhered to at all times.
IBX-660 Industrial Edge Storage Server B.1.2 Anti-static Precautions WARNING: Failure to take ESD precautions during the installation of the IBX-660 may result in permanent damage to the IBX-660 and severe injury to the user. Electrostatic discharge (ESD) can cause serious damage to electronic components, including the IBX-660.
IBX-660 Industrial Edge Storage Server B.1.3 Product Disposal CAUTION: Risk of explosion if battery is replaced by and incorrect type. Only certified engineers should replace the on-board battery. Dispose of used batteries according to instructions and local regulations. Outside the European Union - If you wish to dispose of used electrical and electronic products outside the European Union, please contact your local authority so as to comply with the correct disposal method.
IBX-660 Industrial Edge Storage Server Be cautious of all small removable components when vacuuming the IBX-660. Turn the IBX-660 off before cleaning the IBX-660. Never drop any objects or liquids through the openings of the IBX-660. Be cautious of any possible allergic reactions to solvents or chemicals used when cleaning the IBX-660.
Page 61
IBX-660 Industrial Edge Storage Server The details provided in this appendix are to ensure that the product is compliant with the Peoples Republic of China (China) RoHS standards. The table below acknowledges the presences of small quantities of certain materials in the product, and is applicable to China RoHS only.
Need help?
Do you have a question about the IBX-660 series and is the answer not in the manual?
Questions and answers