Maintenance And Servicing - Central Pneumatic 96469 Set Up And Operating Instructions Manual

Oilless air compressor 155 psi - 26 gallon
Table of Contents

Advertisement

Switch to its "OFF" position. Wait until the Motor cools. Press the Overload
Protector (3) button. Then restart the Air Compressor.
10.
To stop the Air Compressor, turn the Power Switch (2) to its "OFF" position.
Then unplug the Compressor from its electrical outlet. (See Figure b)
11.
Pull the Safety Valve (20) to release any remaining air pressure from the Air Tank
(29). Next, squeeze the trigger on the pneumatic tool to release any remaining
air pressure from the tool. Then, disconnect the air hose from the Air Outlet
Valve (26). (See Figure b)
12.
Remove any moisture from the Air Tank (29) by opening the Drain Valve (33).
Then, retighten the Drain Valve. (See Figure b)
13.
Allow the Air Compressor to completely cool. Then store the Compressor in a
clean, dry, safe location out of reach of children and other unauthorized people.
WARNING
WARNING
1.
bEFORE EACH uSE, inspect the general condition of the Air Compressor.
Check for loose screws, misalignment or binding of moving parts, cracked or
broken parts, damaged electrical wiring, and any other condition that may affect
its safe operation.
2.
AFtER EACH uSE, remove any moisture from the Air Tank (29) by opening the
Drain Valve (33). Then, retighten the Drain Valve. (See Figure b)
3.
AFtER EACH uSE, clean the external surfaces of the Air Compressor with a
clean, moist cloth. Then dry. Do not use solvents. Do not introduce water into
the electrical components of the Air Compressor.
4.
WARNING! if the supply cord of this power tool is damaged, it must be replaced
only by a qualified service technician.
CAutION! All maintenance, service, and repairs not mentioned in this manual
.
must only be performed by a qualified service technician.
SKU 96496
For technical questions, please call 1-800-444-3353.

MAINtENANCE ANd SERVICING

Risk of serious personal injury from accidental starting
or electric shock. turn the Power Switch of the tool to its
"OFF" position and unplug the tool from its electrical outlet
before performing any inspection, maintenance, or cleaning
procedures.
damaged equipment can fail, causing serious personal
injury. do not use damaged equipment. If abnormal noise or
vibration occurs, have the problem corrected before further
use.
Inspection, Maintenance, And Cleaning
Page 11