BUSCH R 5 RA/RC 0010 C Installation And Operating Instructions Manual

BUSCH R 5 RA/RC 0010 C Installation And Operating Instructions Manual

Rotary vane vacuum pumps

Advertisement

Installation and Operating
Instructions
Rotary Vane Vacuum Pumps
R 5 RA/RC 0010, 0016 C
Busch LLC
516 Viking Drive
Va. Beach, VA 23452
Phone: (757) 463-7800
Fax: (757) 463-7407
P/N 0872.918.377 /
0909

Advertisement

Table of Contents
loading

Summary of Contents for BUSCH R 5 RA/RC 0010 C

  • Page 1 Installation and Operating Instructions Rotary Vane Vacuum Pumps R 5 RA/RC 0010, 0016 C Busch LLC 516 Viking Drive Va. Beach, VA 23452 Phone: (757) 463-7800 Fax: (757) 463-7407 P/N 0872.918.377 / 0909...
  • Page 3: Table Of Contents

    Service Centers ......20 Busch – All over the World in Industry ....21...
  • Page 4: Product Description

    In order to improve the operating characteristics the outlet of the (Ú page 8: Conveying Condensable Vapours). The conveyance of pump chamber is equipped with a spring loaded valve. other vapours shall be agreed upon with Busch. The vacuum pump is intended for the placement in a non-potentially Oil Circulation explosive environment.
  • Page 5: Cooling

    15 minutes (Ú page 8: Operation Notes). After turning off the vacuum pump the rically compatible with Busch-vacuum pumps, but do not feature the high retention capacity of genuine Busch-exhaust filters.
  • Page 6: Storage

    However, VCI-products may attack the surfaces of plastics and elastomers. Seek advice from your local packaging dealer! Busch uses CORTEC VCI 126 R film for the overseas packaging of large equipment.
  • Page 7: Suction Connection

    CAUTION In case of very long suction lines it is prudent to use larger line sizes in order to avoid a loss of efficiency. Seek advice from your Busch The connection schemes given below are typical. Depending on the representative! specific order or for certain markets deviating connection schemes may apply.
  • Page 8: Connecting Lines/Pipes

    Star connection (high voltage): CAUTION The vacuum pump is shipped without oil. Operation without oil will ruin the vacuum pump in short time. Prior to commissioning it must be made positively sure that oil is filled in. The vacuum pump is delivered without oil (oil specification Ú page 18: Oil).
  • Page 9: Operation Notes

    (Ú page 8: Conveying Condensable Vapours). The conveyance of erties and can cause a seizure of the rotor. other vapours shall be agreed upon with Busch. Apply a suitable operating method to make sure that no conden- The vacuum pump is intended for the placement in a non-potentially sates remain in the vacuum pump.
  • Page 10: Maintenance

    ● Prior to action that requires touching of the vacuum pump, let the ◆ If appropriate retrofit a gas ballast (Busch Service) and observe vacuum pump cool down, however, if the oil is to be drained, for the chapter Conveying Condensable Vapours (Ú page 8)
  • Page 11: Checking The Colour Of The Oil

    ● Remove the drain plug (i) and drain the oil Checks during Operation When the oil stream dwindles: Busch recommends the use of a filter pressure gauge (available as an ● Reinsert the drain plug (i) accessory). Without filter pressure gauge the filter resistance shall be assessed on the basis of the drive motor current drawn.
  • Page 12: Assessment

    Busch-vacuum pumps, but do not feature the high retention capacity of genuine Busch-exhaust filters and de- teriorate the service life and the efficiency of the vacuum pump due the drive motor draws too much current and/or the pump flow rate to their increased back pressure.
  • Page 13: Removal From Service

    During dismantling of the vacuum pump personal protective www.busch-vacuum.com). equipment must be worn. Busch service will only accept vacuum pumps that come with a com- The vacuum pump must be decontaminated prior to disposal. pletely filled in and legally binding signed “Declaration of Contamina- tion”...
  • Page 14: Troubleshooting

    Replace the connections and/or the tubing (replace with identically dimensioned parts only) A shaft seal is leaking Replace the shaft seal ring (Busch service) An/The exhaust valve is not properly seated Disassemble and reassemble the exhaust or stuck in partially open position...
  • Page 15 Free the vanes or replace with new ones damaged (Busch service) The radial clearance between the rotor and Readjust the vacuum pump (Busch service) the cylinder is no longer adequate Internal parts are worn or damaged Repair the vacuum pump (Busch service) Version with oil return line to the suction connection (RC ...
  • Page 16 Repair the vacuum pump (Busch service) Version with three-phase motor: When connecting the vacuum pump make The vacuum pump was run in the wrong di- sure the vacuum pump will run in the correct rection direction (Ú page 6: Installation)
  • Page 17 Worn coupling element Replace the coupling element Stuck vanes Repair the vacuum pump (Busch service) Use only recommended oils (Ú page 18: Oil) and change more frequently The vacuum pump runs very hot Insufficient air ventilation Make sure that the cooling of the vacuum...
  • Page 18 Clean a clogged oil return line Replace a broken oil return line with an identi- cally dimensioned line, top up oil (if necessary by Busch service) The oil is black Oil change intervals are too long Flush the vacuum pump...
  • Page 19: Oil

    Recommended oil type Busch R 580 l i F n i l y t i . (l) Alternative oil type VM 068 VSL 068 l i F n i l y t i . (l)
  • Page 20: Ec-Declaration Of Conformity

    Note: This Declaration of Conformity and the -mark affixed to the nameplate are valid for the vacuum pump within the Busch-scope of delivery. When this vacuum pump is integrated into a superordinate machinery the manufacturer of the superordinate machinery (this can be the operating company, too) must conduct the conformity assessment process acc.
  • Page 21: Service Centers

    Busch LLC Factory Service Centers California Illinois 13826 Struikman Road 430 Windy Point Drive Cerritos, CA 90703 Glendale Heights, IL 60139 Phone (562) 926-8422 Phone (630) 545-1310 Fax (562) 926-7262 Fax (630) 545-1384 service.ca@buschusa.com service.il@buschusa.com New Jersey Puerto Rico 39 Davis Street...
  • Page 24: Busch - All Over The World In Industry

    Busch – All over the World in Industry www.busch-vacuum.com Australia Norway Dr.-Ing. K. Busch GmbH Busch Australia Pty. Ltd. Niederlassung Nord Busch Vakuumteknikk AS 30 Lakeside Drive Ernst-Abbe-Str. 1-3 Hestehagen 2 Broadmeadows, Vic. 3047 25451 Quickborn 1440 Drøbak Tel: (03) 93 55 06 00...

This manual is also suitable for:

R 5 ra/rc 0016 cR 5 rb 0021 cR 5 rc 0021 c

Table of Contents