Advertisement

Instruction Manual Supplement
R5 Aqua version
Oil-Lubricated Rotary Vane Vacuum Pumps
RA 0165 D, RA 0205 D, RA 0255 D, RA 0305 D
RA 0400 C, RA 0502 C, RA 0630 C, RA 1000 B, RA 1600 B
H
O
2
Ateliers Busch S.A.
Zone industrielle, 2906 Chevenez
Switzerland
0870524638/A0003_en / Original instructions / Modifications reserved
17/02/2021

Advertisement

Table of Contents
loading

Summary of Contents for BUSCH R5 Aqua

  • Page 1 Instruction Manual Supplement R5 Aqua version Oil-Lubricated Rotary Vane Vacuum Pumps RA 0165 D, RA 0205 D, RA 0255 D, RA 0305 D RA 0400 C, RA 0502 C, RA 0630 C, RA 1000 B, RA 1600 B Ateliers Busch S.A.
  • Page 2: Table Of Contents

    Table of Contents Table of Contents 1 Safety ............................3 2 Introduction ..........................4 3 Product Description ........................5 3.1 Application........................6 3.2 Standard Accessories ......................6 3.2.1 Gas Ballast Valve ....................6 3.2.2 Thermostatic Valve ....................6 3.2.3 Temperature Switch "Oil" ..................6 3.3 Optional Accessories ......................
  • Page 3: Safety

    Safety Prior to handling the machine, this instruction manual should be read and understood. If anything needs to be clarified, please contact your Busch representative. Read this manual carefully before use and keep for future reference. This instruction manual remains valid as long as the customer does not change anything on the product.
  • Page 4: Introduction

    2 | Introduction Introduction NOTE Instruction manual supplement. This document is a supplement to the R5 instruction manuals which contents remain valid. It contains additional information in the following chapters: Product Description [► 5], Installation [► 7] and Technical Data [► 8]. 4 / 12 0870524638_RA_Aqua_A0003_IMS_en...
  • Page 5: Product Description

    Product Description | 3 Product Description RA 0165-0305 D Aqua OUT2 OUT1 RA 0400-0630 C Aqua RA 1000-1600 B Aqua Suction connection Inlet filter Discharge connection Condensate drain Temperature switch Water separator NOTE Illustrations In this instruction manual the illustrations may differ from the machine appearance. 0870524638_RA_Aqua_A0003_IMS_en 5 / 12...
  • Page 6: Application

    3.1 Application The machine is intended for the suction of gases which contain a high percentage of wa- ter vapour. Other agents should not be transported. In case of doubt, please contact your Busch representative. 3.2 Standard Accessories 3.2.1 Gas Ballast Valve The gas ballast valve mixes the process gas with a limited quantity of ambient air to counteract the condensation of vapour inside the machine.
  • Page 7: Installation

    In case of very long connection lines it is advisable to use larger line sizes in order to avoid a loss of efficiency. Seek advice from your Busch representative. 4.1.1 Suction Connection Connection size(s): –...
  • Page 8: Technical Data

    Switch point / Trip signal Oil temperature [°C] In case of unfavourable ambient temperature, other oil viscosities may be used. Please consult your Busch repre- sentative for more details. To know which oil has been filled in the machine, please refer to the nameplate (NP).
  • Page 9 Note...
  • Page 10 Note...
  • Page 11 Note...
  • Page 12 Chile Israel Portugal United Arab Emirates info@busch.cl service_sales@busch.co.il busch@busch.pt sales@busch.ae China Italy Romania United Kingdom info@busch-china.com info@busch.it office@buschromania.ro sales@busch.co.uk Colombia Japan Russia info@buschvacuum.co info@busch.co.jp info@busch.ru info@buschusa.com Czech Republic Korea Singapore info@buschvacuum.cz busch@busch.co.kr sales@busch.com.sg www.buschvacuum.com 0870524638/A0003_en / © Ateliers Busch S.A.