Defrost Mechanical Checks Flowchart - Rheem ECONET RP2024BJVCA Installation Instructions Manual

Ariable speed r-410a heat pump outdoor units
Table of Contents

Advertisement

9.0 DIAGNOSTICS & TROUBLESHOOTING

9.9 Defrost Mechanical Checks Flowchart

No
Defrost
Reversing Valve
Stuck
Welded Reversing Valve
Relay on Control Board
Loose Defrost
Sensor
Check Coil
Sensor Connector
62
Defrost
System
Incomplete
Defrost
Sensor in Wrong
Location
Wrong Defrost
Timer Setting
Failed Defrost Relay
on Control Board
(Doesn't stop O.D. fan)
Thermostat Satisfies
During Defrost
Inadequate Indoor
Airflow
Excessive
Defrost
Sensor in Wrong
Location
Low System
Charge
Wind Affecting
in Defrost
Inadequate Indoor
Airflow
Dirty or Restricted
Outdoor Coil
Bad Outdoor
Motor or Fan
Dip Switch #1 on
SW2 is Off