Rheem ECONET RP2024BJVCA Installation Instructions Manual page 14

Ariable speed r-410a heat pump outdoor units
Table of Contents

Advertisement

4.0 INSTALLATION
Table 2A: Refrigerant Line Sizing Chart (English Units)
Allowable
Unit Size
Liquid Line
2.0 Ton
* SEE
NOTE 3
3 Ton
4 Ton
5 Ton
Notes:
1) Do not exceed 150 ft linear line length.
2) Do not exceed 50 ft vertical separation between indoor and outdoor units.
3) * 3/4" vapor line should only be used for 2 ton systems if outdoor unit is below or at same level as indoor
unit to assure proper oil return.
4) ** 1-1/8" vapor line should only be used for 5 ton systems if outdoor unit is below or at same level as indoor
unit to assure proper oil return.
5) Always use the smallest liquid line allowable to minimize refrigerant charge.
6) Applications shaded in light gray indicate capacity multipliers between 0.90 and 0.96 which are not
recommended, but are allowed.
7) Applications shaded in dark gray are not recommended due to excessive liquid or suction pressure drop.
14
20 SEER Variable Speed Heat Pumps
Allowable
Vapor Line
Size
Size
1/4"
5/8"
5/16"
5/8"
3/8"
5/8"
1/4"
3/4" *
5/16"
3/4" *
3/8"
3/4" *
5/16"
5/8"
3/8"
5/8"
5/16"
3/4"
3/8"
3/4"
1/2"
3/4"
3/8"
3/4"
1/2"
3/4"
3/8"
7/8"
1/2"
7/8"
3/8"
3/4"
1/2"
3/4"
3/8"
7/8"
1/2"
7/8"
3/8"
1-1/8" **
1/2"
1-1/8" **
Outdoor Unit ABOVE or BELOW Indoor Unit
Equivalent Length (Feet)
< 25
26-50
Maximum Vertical Separation / Capacity Multiplier
25 /1.00
50 / 0.99
25 /1.00
50 / 0.99
25 /1.00
50 / 0.99
25 /1.00
50 / 1.00
25 /1.00
50 / 1.00
25 / 1.00
50 / 1.00
25 / 0.99
50 / 0.97
25 / 0.99
50 / 0.97
25 / 1.00
50 / 0.99
25 / 1.00
50 / 0.99
25 / 1.00
50 / 0.99
25 / 0.99
50 / 0.98
25 / 0.99
50 / 0.98
25 / 1.00
50 / 0.99
25 / 1.00
50 / 0.99
25 / 0.98
50 / 0.97
25 / 0.98
50 / 0.97
25 / 0.99
50 / 0.99
25 / 0.99
50 / 0.99
25 / 1.00
50 / 1.00
25 / 1.00
50 / 1.00
51-75
76-100
101-125
33 / 0.98
6 / 0.97
50 / 0.98
50 / 0.97
50 / 0.96
50 / 0.98
50 / 0.97
50 / 0.96
33 / 0.99
6 / 0.99
50 / 0.99
50 / 0.99
50 / 0.99
50 / 0.99
50 / 0.99
50 / 0.99
50 / 0.95
50 / 0.93
36 / 0.91
50 / 0.95
50 / 0.93
50 / 0.91
50 / 0.99
50 / 0.98
36 / 0.97
50 / 0.99
50 / 0.98
50 / 0.97
50 / 0.99
50 / 0.98
50 / 0.97
50 / 0.96
50 / 0.95
50 / 0.93
50 / 0.96
50 / 0.95
50 / 0.93
50 / 0.99
50 / 0.98
50 / 0.98
50 / 0.99
50 / 0.98
50 / 0.98
50 / 0.95
50 / 0.93
46 / 0.91
50 / 0.95
50 / 0.93
50 / 0.91
50 / 0.98
50 / 0.97
50 / 0.96
50 / 0.98
50 / 0.97
50 /0.96
50 / 1.00
50 / 0.99
50 / 0.99
50 / 1.00
50 / 0.99
50 / 0.99
126-150
NR
NR
50 / 0.95
50 / 0.95
NR
NR
50 / 0.98
50 / 0.98
NR
NR
20 / 0.96
50 / 0.96
50 / 0.96
50 / 0.92
50 / 0.92
50 / 0.97
50 / 0.97
NR
NR
38 / 0.95
50 / 0.95
38 / 0.99
50 / 0.99

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Econet rp2036bjvcaEconet rp2060bjvcaEconet rp2048bjvca

Table of Contents