Delmhorst P-2000 Owner's Manual
Hide thumbs Also See for P-2000:

Advertisement

P-2000
o w n e r ' s m a n u a l
®
.
TM
W H E N A C C U R A C Y I S T H E P O I N T
GlobalTestSupply
www.
.com
Find Quality Products Online at:
sales@GlobalTestSupply.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P-2000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Delmhorst P-2000

  • Page 1 P-2000 o w n e r ’ s m a n u a l ® W H E N A C C U R A C Y I S T H E P O I N T GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 2 P-2000 Features 3 Key Functions 3 Check Calibration 4 To Set the Scale 4 To Change the Set-Point 5 Information About Your Readings 5 To Check the Accumulated Readings 6 To Reset the Meter 6 Applications...
  • Page 3: 2000 Features

    Read Key Calibration Check Key Scale P-2000 FEATURES h Designed to check the moisture levels in paper products such as cores, corrugated, kraft stock, baled scrap paper, and other paper-based materials h Resistance technology recognized around the world as the...
  • Page 4: Key Functions

    Continued use with a low battery may cause the meter to go out of calibration. If you have a fresh battery and the instru- ment still does not indicate an acceptable calibration, return it to DELMHORST for service. See Service for Your Meter section. Note:...
  • Page 5: To Set The Scale

    Disconnect the battery. Press and hold the Read key for 15 sec- onds. Release the Read key. Press and hold the Check key for 15 seconds. Release the Check key. Connect a fresh battery to the lead wire in a single action, making sure to align the poles prop- erly and without interrupting contact.
  • Page 6: Information About Your Readings

    INFORMATION ABOUT YOUR READINGS Readings below the nominal range of each scale will be dis- played as a negative number. Readings above the nominal range will be displayed with a blinking number. All under- range and over-range readings should be disregarded. They are not added to the accumulated readings or used in calcu- lation of the average or highest reading.
  • Page 7: To Reset The Meter

    TO RESET METER hPress and release the calibration check key hWithin one second, press and hold the scale key . The meter will display a reset sequence as follows: “141”, “7”, “2.0”, “11.1”. The last number, “11.1” is a cali- bration check.
  • Page 8: Using The 0-100 Arbitrary Scale

    Using the 0 –100 Arbitrary Scale This scale is used to test the moisture content of hygroscopic materials for which a calibration is not available. Depending on the material, a special application external electrode, instead of the integral contact pins may be required. Increasing readings on the 0-100 reference scale indicate higher levels of moisture content.
  • Page 9: Care Of Your Meter

    A few meter readings in a limited number of specific areas of a large mass can not be projected to indicate an average moisture content of an entire bale.The readings can be very helpful in providing an indication of the overall moisture con- dition inside the bale and to detect areas of excessive mois- ture.